3.3
START controls wiring
Wire the START control/push-button to
1
and
4
terminals on
JP4
terminal block (N.O. contact).
Additional START controls/push-buttons can be wired in
parallel
(N.O. contact).
3.4
PEDESTRIAN START controls wiring
Wire t
he PEDESTRIAN START control/push-button to
3
and
4
terminals
on
JP4
terminal block (N.O. contact).
Additional PEDESTRIAN START controls/push-buttons can be wired in
parallel (N.O. contact)
3.3.1 TIMER (for permanent opening command) wiring
Wire the TIMER to
1
and
4
terminals on
JP4
terminal block
(N.O. contact).
3.3.2 KEY-SWITCH wiring
Wire
the KEY-SWITCH to
1
and
4
terminals on
JP4
terminal
block (N.O. contact).
3.2
MAIN POWER wiring
Pole disconnect
means must be incorporated according to
current rating.
Connect 230V power to
18 - 19 - 20
terminals on
JP9
terminal block,
paying attention to respect polarity (18 PHASE– 20 NEUTRAL).
POLE
DISCONNECT
DEVICE
PHA
SE
NEUTRAL
PEDESTRIAN
START