background image

K3590-2V1  2/00

REMOTE KEYPADS

6148PL2, 6150PL2, & 6160PL2

INSTALLATION GUIDE

Keypad Features

6148PL2

Fixed-Word

6150PL2

Fixed-Word

6160PL2

2-Line Alpha

Backlit Display

NO

YES (See Note 1)

YES (See Note 1)

Dedicated Function Keys

NO

YES

YES

Built-in Sounder

Piezo

Piezo

Speaker

Notes

1. Permanent display backlighting is an option on some controls (see the control's instructions for details).

GENERAL INFORMATION

WIRING AND INSTALLATION

The 6148PL2, 6150PL2, and 6160PL2 are addressable
Remote Keypads designed for use with the Protection One
250P1 control panel. Addresses are set via the keypad keys
(no DIP switches).

The keys on the keypads are continuously backlit for
convenience.

KEYPAD DISPLAYS AND LEDS

The keypads have the following display features:

Model

Fixed

Word

Display

2-line

Alpha

Display

2-digit

Zone

Identifier

Custom

Zone

Descriptors

6148PL2

X

X

6150PL2

X

X

6160PL2

X

X

The following table shows the LEDs and their functions:

LED

Function

Red

Lights when the system is armed in any mode

Green

Lights when the system is "ready" to be armed.

SPECIAL FUNCTION KEYS

The keypads also feature function keys.  These keys may be
programmed for panic alarms or other special functions
such as macros. See the control's instructions for details.
The 6148PL2 uses the key pairs only.

6150PL2&6160PL2

6148PL2

A ([1] & [*])

[1] & [*]

B ([*] & [#])

[*] & [#]

C ([3] & [#])

[3] & [#]

D

NONE

The keypads can be surface mounted directly to a drywall, or to
a single- or double-gang electrical box.

1.

 

Remove the case back by pushing down two "snaps."
See diagram below.

2.

 

Route wiring from the control panel through the
opening in the case back.

3.

 

Mount the case back to a wall or electrical box.

4.

 

Wire directly from the keypad’s terminal block to the
terminal block on the control board.  Wire functions are
marked next to terminals.  Labels are as follows: DI Data
In to Control Panel, - Ground, + Aux. Power Plus, DO Data
Out of Control Panel.  See the control panel’s Installation
Instructions for more complete details.

5.

 

Re-attach the keypad to its case back.

ARMED

READY

1

2

3

6

5

4

8

9

7

0

*

#

OFF

AWAY

STAY

MAX

TEST

BYPASS

INSTANT

CODE

CHIME

READY

REMOVE CASE BACK BY PUSHING IN THE 2 SNAPS

ALONG KEYPAD'S BOTTOM EDGE AND PULLING THE CASE APART.

Function keys must be held down for at
least 2 seconds to activate an alarm, key
pairs activate immediately.