ATTENTION
: When using this device for exhaust air control,
the shutter must be open to ensure adequate inflow of
fresh air!
KEY
1 Base receiver
2 Window transmitter with reed contact
3 Magnet casing for window transmitter (3a,b,c)
U Packer parts
BASE
(receiver)
4 LED base window open
5 LED base window closed
6 LED base network
TRANSMITTER
8 Transmission control LED
10 Battery compartment cover
MINIMUM OPENING ON WINDOW
This is determined by:
a. The throughput of the air extraction device in m³/h
b. The size of the window to be opened in m²
c. The size of the gap at the window in cm (see Table 1)
Most kitchens are equipped with rectangular combination tilt
& turn windows.
If the window is, for example, round in form, then ask your
specialist installation technician or the district flue & chimney
inspector to calculate the minimum opening.
An example of the required minimum opening for a rectangu-
lar window is shown in the table for tilt/turn adjustment.
Assembly and operating instructions for exhaust
control model AS-510 (wireless version)
Thank you for purchasing the PROTECTOR wireless exhaust
control AS-510.
INTRODUCTION
The operating instructions are a constituent part of this
device. They contain important notes on safety, use and
disposal. Familiarise yourself with all operating and safety
notes before using the equipment. Only use the article as
described and for the listed areas of use. Pass all documents
to the third party if you transfer the equipment
to a new owner.
GENERAL
You can use this device as an exhaust air control device,
as an aid to monitor fresh air supply when commissioning
an exhaust air device (fume extractor hood, fan etc.).This
cannot replace self-monitoring to ensure fresh air supply, but
it can be supportive. This device only activates the exhaust
air system in the event of pressure equalisation when a
window or door is opened. The additional fresh air streaming
in can thus be drawn in from the outside.
This device can also be used to selectively switch devices
or lamps ON or OFF, for instance when a door or a window
is closed or opened. This, for example, enables significant
reduction of energy costs for heating or air-conditioning
devices.