Option 4 - Report Zone Fault
• Enabled, the system will report any zone fault trouble condition to the system controller. This
will not indicate the zone that has the fault as this will be shown on the local keypad and in the
trouble view menu.
• Disabled, no zone fault message will be sent.
Option 5 - Report User Menu Access
• Enabled, the system will report when the master user has accessed the main menu.
• Disabled, no message will be sent when the master access’s the main menu.
Option 6 - Report Local Installer Access
• Enabled, the system will report when the local installer code is used to gain access to the local
installation options.
• Disabled, no message will be sent when the installer access’s the installer menu.
Option 7 - Report Extended Information
• Enabled, the system will report extended information such as the device tamper and fire loop
trouble conditions. These conditions do not generate an alarm in the system locally but can be
used to generate an event at the local monitoring or remote monitoring centre alerting the
operator to a potential problem.
• Disabled, no message will be sent when the extended functions are triggered.
Option 8 - Reserved
!
It is recommended not to enable/disable or modify the settings of reserved
options.
27