13.0 Zones (Menu 3)
The eight zones of the Protégé® EliteSuite® Eclipse LED Keypad can be individually configured as
one of seven zone types and can have specific options assigned to them. The sections Selecting a
Zone, Zone Type and Zone Options are intended to be followed one after the other in order to set
up a zone.
13.1 Selecting a Zone
Step 1
To enter the Zone Number selection menu enter the following key press sequence:
, 3,
Step 2
Select the zone which you wish to view or alter by pressing the number key corresponding the
desired zone. When the number key is pressed the number LED will stay lit to indicate the
selection.
Step 3
Press the
ENTER
key ( ) to confirm your selection.
13.2 Zone Type
Once you have selected a zone,
(refer to section 13.1)
you must select the Zone Type.
Step 1
Select the Zone Type by pressing the number key corresponding the desired Zone Type. When the
number key is pressed the number LED will stay lit to indicate the selection.
Step 2
Press the
ENTER
key ( ) to confirm your selection. Pressing the
MENU
key ( ) will abort the
operation without saving any changes.
You must select a Zone Type from the following list:
Zone Types
1
Disabled
Zone is disabled, does not function in the system.
2
Delay
Zone will have an entry delay when a user enters.
3
Follow
Zone will not cause an alarm if the entry delay has started otherwise the zone will be an instant
zone. Use this to set the Zone Type for a motion detector that is located in an entrance area.
4
Instant
Zone will cause alarm immediately.
5
24hr
Zone will always cause an alarm immediately.
6
Fire
Zone is a fire zone and will generate and instant alarm.
7
Fire Delay
Zone is a delayed fire zone and will generate the fire delay beeping and require the user to follow
the delay fire zone procedures to prevent a full fire alarm from being activated.
29