15.2 Installer Menu
To enter the Installer menu press the
ENTER
key ( ), then enter the four digit Installer code.
Key Sequence
Description
,1, 1,
View the Entry Delay Timer
,1, 1, [T1], [T2], [T3],
Change the current Entry Delay Timer
,1, 2,
View the current Exit Delay Timer
,1, 1, [T1], [T2], [T3],
Change the current Exit Delay Timer
,1, 3,
View the current Siren Timer
,1, 1, [T1], [T2], [T3],
Change the current Siren Timer
,2, 1, [toggle options],
General settings
Option
Description
Default
1
Enable EOL Zone Option (1k + 1k)
Disabled
2
Enable Duplex Zone option (8 zones)
Disabled
3
Beep on trouble condition
Disabled
4
Power up disarmed
Disabled
5
Reserved
Disabled
6
PGM output follows alarm state
Enabled
7
PGM output follows area state
Disabled
8
PGM output inversion
Disabled
,2, 2, [toggle options],
Arming Options
Option
Description
Default
1
Allow Fast Regular arming
Enabled
2
Allow Fast Stay arming
Enabled
3
Allow Instant Arming during Stay exit
Enabled
4
Allow Fast Force arming
Enabled
5-8
Reserved
Disabled
,2, 3, [toggle options],
Reporting Options
Option
Description
Default
1
Report Arming and Disarming
Enabled
2
Report Alarms
Enabled
3
Report Zone Bypass
Disabled
4
Report Zone Fault
Disabled
5
Report User Menu access
Disabled
6
Report Local Install Menu access
Disabled
7
Report Extended Information
Disabled
8
Reserved
Disabled
42