2. Remove the bolts.
Remove the grip.
winch
grip
1. Unscrew four M10
nuts on the bolts
fastened the grip to the
winch in RUP 502
device.
M10 bolts
2. Remove the bolts.
Remove the grip.
winch
grip
1. Unscrew two M10
nut fastening the grip
to the winch of RUP
502-A / 502-B device.
M10 nuts
max. 60
130
2.0
max. 25mm
M10 bolts
M10 washers
(DIN 125A)
M10 self-locking nuts
(DIN 985)
10
10
45
INSTALLING DEVICE ON A STRUCTURAL ANCHOR ELEMENT
It is possible to install device directly on the structural anchor element like flat surface (e.g. wall) or steel profile. The structural
anchor element to which the device is fastened must have stable construction and have minimal static strength of 14 kN.
Construction and fastening of the structural anchor element must prevent of accidental disconnection of the device. To install
device on the structural anchor element we must remove the grip which is designed to be used only with the tripod.
REMOVING THE GRIP OF THE RUP 502 DEVICE
REMOVING THE GRIP OF THE RUP 502-A / 502-B DEVICES
INSTALLING ON THE FLAT SURFACE
Device should be installed using two holes ( 10 mm and oblong 10x45) situated on the back wall of the winch.
1.
Install winch using two M10 steel mechanical or chemical anchor bolts. Anchors should be installed in accordance with the
2.
installation instructions provided by the manufacturer of the anchors.
Pu the washer M10 (DIN 125A) under each nut. Tighten two M10 self-locking nuts (DIN 985).
3.
INSTALLING ON THE FLAT SURFACE (SCREWS)
Device should be installed using four 13 mm holes situated on the back wall of the winch.
1.
Install device using four M12 steel bolts. Put the bolts through the back wall of the winch and through the holes of the
2.
structural anchor surface.
Put the washers 13 mm (DIN 125A) under the head of each bolt and under each nut. Tighten four M12 self-locking nuts
3.
(DIN 985).