5.
TIME OF USAGE
Maximum time of usage of correctly operating
devices is unlimited.
The device must be withdrawn from use
immediately and destroyed if it has been used to arrest a fall
or there are any doubts concerning its function.
NOTE:
Maximum time of usage of the device depends on
intensity and environment of use. If the device is used in
heavy conditions, being exposed to frequent contact with
water, sharp edges, corrosive substances, extreme
temperatures, it may be necessary to withdraw the device
after only one use.
6.
PERIODIC INSPECTIONS
At least once a year, after every 12 months of use, it
is necessary to carry out periodic detailed inspection of the
device.
Periodic inspection can be carried out by a properly
qualified and skilled person.
After 5 years of use, it is recommended that periodic
inspections are carried out by the manufacturer of the
equipment or an entity authorised by the manufacturer to
carry out such inspections.
Figure 2
– Permissible load direction
3. TRANSPORT AND WEIGHT
Weight of complete device: 9kg.
The equipment must be transported in a package (e.g.:
bag made of moisture-proof textile or foil bag or cases made
of steel or plastic) to protect it against damage or moisture
.
4. MAINTENANCE AND STORAGE
The device should be cleaned and disinfected without
causing adverse effect on the materials which the device is
made of. For textile materials (webbings, ropes) use agents
suitable for delicate fabrics. Can be washed in hands or in a
washing machine. Rinse thoroughly. Wash textile elements
with water only. - If the equipment becomes wet, either when
cleaning or in use, allow it to dry naturally, and keep it away
from any sources of heat. In metallic products slightly
lubricate some mechanical parts (springs, hinges, pawls,
etc.) on a regular basis to improve their operation.
The device should be stored loosely packed in well-
ventilated rooms, protected from direct light, UV degradation,
dust, sharp edges, extreme temperatures and aggressive
chemical substances.
7.
TABLE NO. 1 - POSSIBLE INSTALLATION
OF HOIST RUP507
DEVICE
UNIVERSAL HOLDER
COMPACT GANTRY
KSB / FSB / KSB-LE
KSB100-352-003
(standard hoist equipment)
KSB100-350-000
(standard gantry equipment)
8.
OVERALL DIMENSIONS
L [mm]
W [mm]
H [mm]
257
173
450
Figure 3
– Overall dimensions of device
.