RS232 Communication
ProTelevision Technologies
PT 5780 DVB-T Modulator
Instruction Manual
Revision 3.11
6-26
6.3.3
Instrument commands
6.3.3.1
DIAGnostic subsystem
Command
Parameter
Status after
Factory Reset
Remarks
:DISPlay
-
No query. No action
:ERRorqueue?
-
-
Query only. No action
:ERRorqueue
:RESet
-
-
No query. No action
6.3.3.2
SYSTem subsystem
6.3.3.3
USER subsystem
Command
Parameter
Status after
Factory Reset
Remarks
:NAMe
<”Name”>
String data
6.3.3.4
DISPlay subsystem
Command
Parameter
Status after
Factory Reset
Remarks
:CONTrast
0 to 100 %
25
Command
Parameter
Status after
Factory Reset
Remarks
:PRESet
[:RECall]
1 to 10
-
:STORe
1 to 10
-
No query.
:NAMe
1 to 10,<”Name”>
-
Name – string data
format. Query command
format is
:PRES:NAME? <System
Preset No. 1 to 10>.
:DATE
<YYYY,MM,D>
2002,01,01
:TIME
<HH,MM,SS>
00,00,00
:OINStalled
<”xxxx.xxxx.xxxx.xxxx”>
String data format
:OUSed
<”101001….”>
String data format
consisting of 1’s and 0’s
:COMMunicate:
SERial:TRANsmit
:BAUD
<Port no.>,<Baudrate>
1 | 2 ,
1200 | 2400 | 4800 | 9600 |
19200 | 115200
On both ports -
19200
:FRES
See Chap. 4.4
No query.