D. PRESET PROGRAMS : 

PROGRAM 2 TO PROGRAM 7 ARE THE PRESET PROGRAMS. PRESS  ENTER  KEY TO 
SELECT TIME ( OR DISTANCE ) AND AGE. THEN, PRESS  ¡¶ OR ¡¿ KEY TO ADJUST THE 
VALUES. USERS MAY EXERCISE WITH DIFFERENT LEVEL OF LOADING IN DIFFERENT
COLUMNS AS THE PROFILES SHOW. AFTER PRESSING  START / PAUSE  KEY TO 
EXERCISE, PLEASE ALSO APPLY THE HEART RATE DETECTOR     OR     TRANSMITTER 
APPROPRIATELY.  USERS MAY ALSO EXERCISE IN ANY DESIRE LEVEL ( BY PRESSING     
OR DURING THE WORKOUT ) WITH A PERIOD OF TIME OR A CERTAIN DISTANCE. WITH 
THE INPUT OF AGE, THE COMPUTER MAY SUGGEST A TARGET HEART RATE TO
EXERCISE. THE SUGGESTED HEART RATE IS 85% AS THE FORMULA CALCULATED 85% 
( 220  AGE ). WITHOUT THE INPUT OF AGE, THE COMPUTER MAY SETUP THE DEFAULT 
VALUE BE 161 AS FORMULA 85% ( 220  30 ). IF THE HEART RATE DETECTED EQUALS TO 
OR GREATER THAN THE TARGET H.R., THE VALUE OF HEART RATE WILL KEEP FLASHING. 

PLEASE NOTE THAT IT IS A WARNING FOR USERS TO SPEED DOWN OR TO LOWER THE 
LEVEL OF LOADING

.

E. BODY FAT PROGRAM :

PROGRAM 8 IS A SPECIAL PROGRAM DESIGNED TO CALCULATE USERS' BODY FAT RATIO 

AND TO DESIGN A SPECIFIC LOADING PROFILE FOR USERS. WITH 9 DIFFERENT BODY 

TYPES, THE COMPUTER CAN GENERATE 9 DIFFERENT PROFILES FOR EACH. PRESS  
ENTER  KEY TO SELECT GENDER, HEIGHT, WEIGHT, AND AGE. THEN, PRESS      OR     KEY 
TO ADJUST THE VALUES. AFTER PRESSING  START / PAUSE  KEY TO CALCULATE BODY 
FAT, PLEASE ALSO APPLY THE HEART RATE DETECTOR APPROPRIATELY.

 

IF IT HAPPENS, 

PRESS  START / PAUSE  KEY TO CALCULATE AGAIN. THEN, THE CALCULATION VALUES OF 
FAT%, BMR, BMI, BODY TYPE, AND A DESIGNED PROFILE WILL SHOW UP SHORTLY. 
PRESS START / PAUSE  KEY TO EXERCISE. THE PROFILE SHOWN IN THE DISPLAY IS 
SPECIALLY DESIGNED FOR YOUR BODY TYPE. THE TARGET HEART RATE WILL SETUP AS :
TYPE1~3 S 55% * ( 220-AGE ) TYPE4~6 IS 65% * ( 220-AGE ) TYPE7~9 IS 75%*( 220-AGE )
IF THE HEART RATE DETECTED EQUALS TO OR GREATER THAN THE TARGET H.R., THE 
VALUE OF HEART RATE WILL KEEP FLASHING. 

PLEASE NOTE THAT IT IS A WARNING FOR 

USERS TO SPEED DOWN OR TO LOWER THE LEVEL OF LOADING

.

F. ERROR MESSAGE : " E3 " 

ONCE YOU DO NOT PUT YOUR HANDS ON THE SENSOR OR FIRMLY GRASPED, THE 
SCREEN WILL SHOW " E3 " .
TO SOLVE THIS PROBLEM, PLEASE PRESS THE MEASURE BUTTONS ONCE AGAIN, AND 
HOLD ON THE SENSOR WITH STRAIGHT ARMS IMMEDIATELY. PLEASE DO NOT MOVE 
YOUR BODY WHILE MEASURING. 
NOTE : ONLY UNDER THE HAND PULSE FUNCTION AND THE BODY FAT WORKS.

G. HEART RATE CONTROL PROGRAMS :

PROGRAM 9 TO PROGRAM 12 ARE THE HEART RATE CONTROL PROGRAMS. IN 
PROGRAM 9, PRESS  ENTER  KEY TO SELECT TIME ( OR DISTANCE ) AND TARGET H.R. 
USERS MAY SETUP A TARGET HEART RATE TO EXERCISE IN A PERIOD OF TIME OR A 
CERTAIN DISTANCE. IN PROGRAM 10 TO PROGRAM 12, PRESS  ENTER  KEY TO SELECT 
TIME (  OR DISTANCE ) AND AGE. THEN,  PRESS      OR       KEY TO ADJUST THE  VALUES. 
USERS MAY EXERCISE IN A PERIOD OF TIME OR A CERTAIN DISTANCE WITH 60% MAX 
HEART RATE IN PROGRAM10, 75% MAX HEART RATE IN PROGRAM 11, AND 85% MAX 
HEART RATE IN PROGRAM 12. AFTER PRESSING  START / PAUSE  KEY TO EXERCISE, 
PLEASE ALSO APPLY THE HEART RATE DETECTOR APPROPRIATELY.  IN THESE 
PROGRAMS, THE COMPUTER WILL ADJUST THE LEVEL OF LOADING ACCORDING TO THE 
HEART RATE DETECTED. FOR EXAMPLE, THE LEVEL OF LOADING MAY INCREASE WHILE 
THE HEART RATE DETECTED IS LOWER THAN TARGET H.R. ALSO, THE LEVEL OF 
LOADING MAY DECREASE WHILE THE HEART RATE DETECTED IS HIGHER THAN TARGET 
H.R. AS A RESULT, THE USER'S HEART RATE WILL BE ADJUSTED TO CLOSE THE TARGET 
H.R. IN THE RANGE OF TARGET H.R. 5 AND TARGET H.R. +5.

 

 

 

- 6 -

Summary of Contents for IMT-7500

Page 1: ...M AND WATT SHOW AT THE SAME TIME OR THE VALUES OF SPEED AND CAL DO BY PRESSING IT D UP SELECTS OR INCREASES THE VALUES OF PROGRAMS GENDER HEIGHT WEIGHT TIME DISTANCE WATT TARGET HEART RATE AGE AND 10...

Page 2: ...ON THE PROGRAMS G RPM SPEED KM H MPH DISPLAY INDICATES ONLY 1 VALUE OF RPM SPEED OR KM H MPH DISPLAYED DEPENDING ON THE PROGRAMS KM H OR MPH WILL DISPLAY WHEN CURRENT SHOWS UP H DISTANCE FAT DISPLAY...

Page 3: ...R OF ADAPTOR THE ADAPTOR SPECIFICATION REQUEST 6VDC 1A OUTPUT C THE VARIABLES MAY NEED TO CHANGE IN THE PROGRAMS PLEASE NOTE THAT ONLY 1 VALUE OF TIME OR DISTANCE CAN BE ADJUSTED BOTH ADJUSTMENTS DO N...

Page 4: ...ODY FAT PROGRAM 4 HEART RATE CONTROL PROGRAMS 2 USER SETTING PROGRAMS 1 WATT CONTROL PROGRAM AND 1 PULSE RECOVERY MEASURING E PROGRAM GRAPH EACH GRAPH SHOWN IS THE PROFILE OF THE LOADING IN EACH COLUM...

Page 5: ...PIECES OF METAL PARTS THE CORRECT WAY TO GET DETECTED IS TO GENTLY HOLD BOTH METAL PARTS EACH HAND WITH THE GOOD SIGNALS PICKED UP BY THE COMPUTER THE HEART MARK IN THE HEART RATE BODY TYPE DISPLAY S...

Page 6: ...E SHOWN IN THE DISPLAY IS SPECIALLY DESIGNED FOR YOUR BODY TYPE THE TARGET HEART RATE WILL SETUP AS TYPE1 3 S 55 220 AGE TYPE4 6 IS 65 220 AGE TYPE7 9 IS 75 220 AGE IF THE HEART RATE DETECTED EQUALS T...

Page 7: ...EXERCISE THE SUGGESTED HEART RATE IS 85 AS THE FORMULA CALCULATED 85 220 AGE WITHOUT THE INPUT OF AGE THE COMPUTER MAY SETUP THE DEFAULT VALUE BE 161 AS FORMULA 85 220 30 IF THE HEART RATE DETECTED E...

Reviews: