EMERGENCY
OPENING:
K
EY
O
VERRIDE
:
1. I
NSERT THE
P
OWER
O
VERRIDE
J
ACK
INTO THE
C
OVER
R
EMOVAL
H
OLE
AND PUSH UPWARDS
.
2. G
ENTLY REMOVE THE
K
EYHOLE
C
OVER
AND INSERT THE TUBULAR KEY
.
3. T
URN THE KEY CLOCKWISE
(
RIGHT
)
AND THEN TURN THE KNOB TO OPEN
THE SAFE
.
P
OWER
O
VERRIDE
:
1. I
NSTALL
4
NEW BATTERIES IN THE
P
OWER
O
VERRIDE
B
OX
AND PLUG THE
P
OWER
O
VERRIDE
J
ACK
INTO THE
P
OWER
O
VERRIDE
H
OLE
.
2. O
PEN THE SAFE BY FOLLOWING
S
TEP
1
.
3. O
PEN BATTERY COVER AND INSTALL
4
NEW BATTERIES
.
4. C
LOSE BATTERY COVER
,
THE SAFE GOES BACK TO NORMAL OPERATION
MODE
.
NOTE:
T
HE SAFE KEEPS THE CODE IN MEMORY UP TO
6
MONTHS WITHOUT
POWER
.
TIPS:
•
U
SE DIGITS
1
–
0
TO ENTER YOUR CODE
.
•
U
SE THE
*
KEY AS BACKSPACE TO CLEAR THE LAST DIGIT
.
•
H
OLD THE
*
KEY FOR MORE THAN
2
SECONDS TO CLEAR THE
LCD
D
ISPLAY
.
•
IF YOU ENTER A WRONG CODE THE
LCD
D
ISPLAY
WILL SHOW
ERROR
.
•
I
F YOU ENTER A WRONG CODE FOR THREE CONSECUTIVE TIMES THE
LCD
D
ISPLAY
WILL SHOW
ERROR
AND THE SAFE WILL BE LOCKED
FOR
3
MINUTES
.
A
FTER
3
MINUTES THE SAFE WILL RETURN TO
NORMAL OPERATION MODE
.
•
W
HEN THE
LCD
D
ISPLAY
SHOWS
LO-BAT
IT IS HIGHLY
RECOMMENDED TO CHANGE THE BATTERIES AS SOON AS POSSIBLE
.
U
SER
’
S
M
ANUAL
F
OR
E
LECTRONIC
S
AFE
M
ODELS
:
HD-20, HD-23, HD-25, HD-34, HD-45, HD-
53, HD-63A, HD-63B, HD-63C, HD-73, HD-
100, HD-120, HD-150, HD-34C
R
EV
.
092606
4