SETTINGS

DISPLAY

ADJUSTMENT RANGE

DEFAULT

Temperature  

calibration

Adj

-5°C  to  +5°C

-2.5°C

Schedule mode

PrG

5 + 2 / 6 + 1 / 7

5 + 2: Monday to Friday set the same; Saturday to Sunday set the same

6 + 1: Monday to Saturday set the same; Sunday set individually

7: Monday to Sunday set the same 

5 + 2

Antifreeze

LtP

ON: Enable    OFF: Disable

OFF

Sensor /  

Temperature Control 

mode

Sen

IN

 – Built-in internal control – room sensor only

OUT

 – External control, floor sensor only

ALL

 – Dual temperature control; internal room temperature sensor and 

external sensor with overheating protection

IN

External  

temperature limiter

tOP

40 to 80°C

When the sensor mode is set to ALL this sets a temperature limit on the 

external sensor for overheating protection

50°C

Internal sensor 

hysteresis

dt0

0.5°C to 4°C  - For example, if the

internal sensor is set to 20°C with the default set to 1°C, then at higher 

than 21°C the heater turns off and at lower than 20°C the heater turns on

1°C

External sensor 

hysteresis

dt1

0.5°C to 5°C  

3°C

Backlight status

bL

ON – 

Always on 

OFF – 

Auto turn off after 5 seconds

OFF

Status at re-power

Sat

ON – 

The same as previous

OFF – 

Off status every time

Keep this setting as default - OFF

OFF

Restore factory 

settings

deF

Restore to factory settings

 

ADVANCED FUNCTION SETTINGS

Press ON/OFF until the sub-display shows OFF,  
press ON/OFF again, then immediately press Menu.  
You are now in the Advanced Function Settings. The first 
display will be Adj. 
Press Menu to navigate through the 
menu items. Use UP or DOWN to change the settings.

To save the data go through the functions then exit at any 
time by pressing the menu key.

WARNING: The settings are used to set some important 
parameters of the system and the thermostat has already 
been debugged and tested by professionals, there is no 
need to reset. 

Do not make any improper modifications and permit 
changes only by a qualified person.

Summary of Contents for Touchscreen Thermostat

Page 1: ...y cleaning Wiring details These are printed on the back of the thermostat casing The floor sensor is connected to terminals T1 T2 please note there is no polarity and the twin core sensor cable can be connected either way The 230V electrical supply connects to terminals L Live N Neutral The heating mat s connect to terminals L1 Live N1 Neutral Earth connections are made with the back box When the ...

Page 2: ...previous settings Finally press ON OFF twice to confirm If you want to turn off a period then in the temperature setting for the period press DOWN until OFF is displayed in the temperature screen then press Menu to confirm To quickly return to the original display press ON OFF twice The system default is 5 2 and the default settings are as the following table For example when the system time is Fr...

Page 3: ...ault set to 1 C then at higher than 21 C the heater turns off and at lower than 20 C the heater turns on 1 C External sensor hysteresis dt1 0 5 C to 5 C 3 C Backlight status bL ON Always on OFF Auto turn off after 5 seconds OFF Status at re power Sat ON The same as previous OFF Off status every time Keep this setting as default OFF OFF Restore factory settings deF Restore to factory settings ADVAN...

Page 4: ...deformed correct it Large deviation of measured temperature and the actual temperature a The thermostat should be installed in a ventilated room and never in direct contact with sunlight or localised heaters b Check terminal connections including the sensor INSTALLATION A Hook B Central fixing lug 1 Remove the bezel to start the installation by pushing the bezel away from the main body of the ther...

Reviews: