37
UPC-A
Read: Format
System character
Data digits (10 digits)
Check digit
Check digit verification: The check digit verification is optional.
Check digit trans.: By setting Enable, check digit will be transmitted.
Code ID setting: Code ID is a one-or-two-character string used to represent the symbol upon a
succeeding reading. If you want application to transmit Code ID, you must set Code ID transmission to
be enabled. Refer to the chapter of String transmission.
Insertion group selection: Refer to Global insertion group selection of the chapter of Hand-held scan &
some global settings.
Supplement digits: The Supplement digits barcode is the supplemental 2 or 5 characters.
Format
System character
Data digits (10 digits)
Check digit
Supplement digits 2 or 5
Truncation/Expansion:
Truncate leading zeros The leading “0” digits of UPC-A data characters can be truncated when the
feature is enabled.
Expand to EAN13 It extends to 13-digits with a “0” leading digit when the feature is enabled.
Truncate system character The system character of UPC-A data can be truncated when the feature is
enabled.
Add country code The country code (“0” for USA) can be added when the feature is enabled.