Description 

 

The unit DTLED can be used to control the operation of 
cirlucation pump of a solar system based on temperature 
difference between solar (boiler,stove,etc) and water tank. 
Also it can control supplementary heating of water tank up to 
a preset temperature. 

Features:  

1.  Frost and overheat protection of solar and tank. 
2.  Separate outputs for circulation pump and supplementary 

heater of up to 5A. 

3.  Monitors two temperatures. 
4.  Fast and easy programmable - 4 main settings and one user defined parameter.  
5.  Modes of operation - „Auto” /”Holliday” easily selectable by a slide switch at front panel. 
6.  „Eco function” – postponds the heater activation if solar is active (if “there is sun” the 

supplementary heater is switched off) – this mode can activated/deactivated by by user 
at any time. 

7.  2 pcs. PTC temperature 

probes 

– silicon cable 0.3m –PTC 1k  

8.  2 separate  Relay outputs for: 

-

  Р1 – SPDT (N.O. +N.C.) contact. Outputs “live” for pump or valve (on and off) controll 

-

  Р2 – SPST (N.O) contact for activation of suplimentary heater 

9.  LED display with 2 digits and 6 additional LEDs for indication. 
10. Buttons – 1pcs.  
11. Easy setup – each main setting can be selected among a set of fixed values. 
12. Main parameters setting – selectable by changing jumper location: 

-

  maximal temperature in tank: +65; +75; +85 °C  

-

  frost protection of solar (forced activation of pump): -25; -10; +5 °C  

-

  minimal temperature of solar to enable circulation based on dT: +40; +50 °C  

13. Setting of dT (differential temperature – solar to tank) by a knob – fine : from 3 to 25°C 
14. Setting of tank temperature (supplementary heating) – using push button on front 

panel: st25°C up to maximal temperature allowed in 5°C step;  

15. Manual test/activation of pump – holding the push button on front panel. 

 

ЕСELECTRICAL WIRING 
 

  

 

 

-

  Power supply 220V AC – internal and pump – term. 21 (Live in “L”) / 18 („N”-neutral)  

-

  Pump output (N.O) – term.  19 (Live output) / 17 („N”-Neutral) 

-

  Supplimentary heater (N.O.)–  temr. 16 and 15  -5A max 

 

* Additional external fuse should be connected to term.21 of up to 6A.  

 - Sensors   

TS1 – term.5,6 –  tank temperature    

TS2 – term 7,8 – solar tempetature. 

 
 

----------- PROXEL ENGINEERING -------------------- www.proxel-bg.com------------------------------ DTLED rev. 1.6/06.2015------       
 

 

           

2

OPPERATION 

    Front pannel:

 

                          

 

 
 - “1” – LED indicator of tempetature (2 digits). Mostlly displays tank t° and each 10 sec. displays 
solar t° for 2 sec. (if tank t° is displayed LED#6 is ON, if solar t° is displayed LED#9 is ON). 

- “2” – slide switch for mode selection („Auto” / „HOLLIDAY”) 
- “3” – push button 
- LED “4” – if “On”, the displayed value is over 100°C. (if display=’25’ and LED#4 is ON means 

t° =123°C) 

- LED “5” – if “On”, negative displayed value (if display=’10’ and LED#5 is ON -  t° = -10°C) 
- LED “6” – if “On” displayed value is for tank tank temperature. If blinks – possible probe failure 
- LED “7” – if “On” – pump is active 
- LED “8” – if “On” – heater is active 
- LED “9” – if “On” – displayed value is for solar temperature. If blinks – possible probe failure. 
- If LED 9 and LED 8 blinks alternatively – dT value is displayed 

 
Button operation: 

 1.

 

When pressed shortly, the following information is displayed sequentially:  

-

  boiler and solar temperatures - automatically alternating each 3 sec. 

-

  differential temperature (dT) setting. The temperature is alternated with the symbols "dt";  

-

  maximal  allowed  temperature  in  the  tank.  The  temperature  alternates  with  the  symbols 

"bH"; 

-

  Minimal  temperature  of  solar  to  enable  circulation.  The  temperature  alternates  with  the 

symbols "cS" (Collector Start);  

-

  Temperature  setting  for  anti  freezing  protection.  The  temperature  is  alternated  with  the 

symbols "cd" (Collector Defrost); 

 2.

 

When pressed and holded for 3-4 seconds displays/changes the temperature of the tank’s 

thermostat. The temperature alternates with "bt" / "bE" (Standard / Eco tank thermostat);  

-

  Each  subsequent  pressing  increases  the  set  temperature  by  5  degrees.  If  the  set 

maximum temperature in the tank is exceeded, the value returns to 15 ° C.  

-

  Switching  between  standard  and  Eco  tank  thermostat  is  cyclical,  each  time  when  the 

maximal tank temperature is exceeded. The symbols changes "bt" to "bE" and the mode is 
changed also.  

3.

 

When  pressed  and  holded  for  more  than  10  seconds,  the  pump  is  manually  activated  –  as 

long the button is pressed; 
   *

 

To return to the basic mode leave the device without pressing the button for 1 minute. 

 
Choosing an operation mode 

-

  for normal operation "Auto mode" - move the slider to the "left" to position “Auto” 

-

  to operate in holyday mode “vacation” mode - move the slider to the "right" 

 
Faulty sensor alarm

 - the corresponding indicator "6" or "9" blinks rapidly. 

 
To change most settings, you need to remove the product’s cover

 