Configuration
MP.11 4954-R Installation and Management
Management Parameters
84
Serial Configuration Settings
The serial port interface on the unit is enabled at all times. See “Serial Port” in the
Tsunami MP.11 Reference Manual
for
information about how to access the CLI interface through the serial port. You can configure and view following
parameters:
•
Serial Baud Rate:
Select the serial port speed (bits per second). Choose between 2400, 4800, 9600, 19200, 38400,
or 57600; the default Baud Rate is 9600.
•
Serial Flow Control:
Select either None (default) or Xon/Xoff (software controlled) data flow control. To avoid
potential problems when communicating with the unit through the serial port, Proxim recommends that you leave the
Flow Control setting at None (the default value).
•
Serial Data Bits:
This is a read-only field and displays the number of data bits used in serial communication (8 data
bits by default).
•
Serial Parity:
This is a read-only field and displays the number of parity bits used in serial communication (no parity
bits by default).
•
Serial Stop Bits:
This is a read-only field that displays the number of stop bits used in serial communication (1 stop
bit by default).
The serial port bit configuration is commonly referred to as 8N1.