48
C) Verify that you are not duplicating IP addresses on your
network.
D) Verify the Access Point diskette is seated properly inside the
RangeLAN2 7500.
2.
No response from the RangeLAN2 7500 when configur-
ing locally. There are several possible solutions for this
problem:
A) Verify that SLIP.BAT is configured for the correct I/O port
address and IRQ interrupt of the configuration PC's COM
port.
B) Verify that there are no IRQ conflicts between the configu-
ration PC's COM port and other cards in the computer.
C) Verify that you are using a null modem serial cable when
attaching a configuration PC to the RangeLAN2 7500.
D) Verify the Access Point diskette is seated properly inside the
RangeLAN2 7500.
3.
Mismatched domains and security IDs. If you are unable
to establish communication with another machine on the
network, it is possible that you do not have the same
domain and security ID as on the other machine.
4.
The SNMP management system is unable to write
parameters. Verify that you are using “Private” for the
community string.
5.
You cannot communicate through the RangeLAN2
7500 to the rest of the Ethernet network. Follow these
steps to diagnose the problem: