Connect to Controller
Step 1:
Connect the 5 wires from the Edge Reader Enclosure (outside)
unit to the 5 wires from the Edge Relay Enclosure (inside) unit
based on corresponding colors
Step 2:
Connect the brown and blue wires of the Edge Relay Enclosure
(inside) unit to the two wires from the REX input of the access
controller
Step 3:
Connect the black (GND) and red (+VDC) wires to a power
source (this could be provided by the controller) equivalent to
what is needed to power the electri ed lock
Door Contacts
The DPS+ and DPS- lines are intended for use with door contacts. For install instructions and current
status, please visit: https://proxy.com/s/edge-install
.
|
16
User Manual and Installation Guide: Proxy Mobile Reader Edge
This document may have been updated since printing — for the latest, please visit https://proxy.com/s/edge-install