Factory Settings
Gas/Electric
20 minutes
60 seconds
ProR80J-XX
Heating
2 minutes
2 minutes
Off
Gas
o
160 F
o
45 F
Zone1
External Barometric
Equal
Off
Off
Weighted Zones
o
55 F
On
Off
Gas/Electric, conventional or dual fuel heat pumps.
o
40 to 60 F. Requires outdoor temperature sensor.
External Barometric or adjusting damper close position. .
Selections
Options and Factory Settings, All Zoning Panels
30 to 240 seconds.
Equal or different.
5 to 240 minutes.
Heating or cooling.
0 to 10 minutes.
0 to 10 minutes.
On or Off.
Gas or electric.
Weighted Zones calling.
o
110 to 180 F
o
37 to 55 F
ProR80J-XX
On or Off
On or Off.
On or Off.
On or Off
Zone1.
Opposite System Service
Moderate Weather Limit
Moderate Weather Temp
Opposite System Time
Staging Calculations
Minimum Run Time
Minimum Off Time
Fresh Air Control
Indoor Fan Mode
Em Heat Control
Timed Upstaging
High DAT Limit
Low DAT Limit
Dampers Used
Purge After Call
Priority System
Zone Sizes
Purge Time
Equipment
Bypass
Option
Select Equipment
By Clone Y/N
Change Equipment
Options Y/N
Change Zone Size
Y/N
Change Tstat
Options Y/N
Installer Menu
Press and hold the MENU key for 4 seconds to access the
Installer menu. The PDMi3 displays “Waiting for Data” while it
reads the panel settings. The MAIN menus are shown below.
Press Yes to use a previously saved
configuration to clone this panel to the
same settings. Press No to continue.
Press Yes to set the number of stages of
heating and cooling, the fan operation,
the supply air temperature limits, outdoor
changeover temperature for dual fuel
heat pumps and number of zones being
used. Press No to continue.
Press Yes to change the size of each
zone. The zone size is set in a weighted
value from 0.5 to 2.0. A small zone might
be 0.5 and a large zone might be 1.5
zones. Be sure the total is equal to the
total number of zones. Press No to
continue.
Press Yes to change the type of
thermostats used. When heat pump
equipment is selected, the Zone1
thermostat may be a heat/cool or heat
pump type and the reversing valve
operation (O or B) can be selected.
Change Staging
Options Y/N
Change Bypass
Options Y/N
Press Yes to change the staging using
the weighted zones calling and the timer.
Each stage can be set to turn on at the
same or different weighted zones calling
at the time. Or a stage can be delayed
and set to turn on after the call has been
active for a number of minutes.
The delayed option can be used to meet
the new Title24 requirement to delay
auxiliary strip heating in a conventional
heat pump.
Timers can be set to override capacity
staging and activate each stage after the
call time has reached a number of
minutes. Press No to continue.
Press Yes to change the bypass options.
Bypass can be achieved using the non-
calling zone dampers, using the Close
stop position or a bypass duct between
the supply and return controlled by a
barometric damper. Press No for other
menu selections.
8
See page 10 for more information.
See page 10 for more information.
See page 11 for more information.
See page 10 for more information.
See page 9 for more information.