PZ2 Series Manual

 

PROZONE INTERNATIONAL, Inc. Ozone Water Purification Systems 

 

INSTALLATION GUIDE and  

OPERATION MANUAL 

 

Prozone PZ2 Series 

 

Ozone Generator Systems 

 

  

SAFETY

  

READ AND FOLLOW ALL INSTRUCTIONS. 

 

IMPORTANT SAFETY INSTRUCTIONS 

 

1.  All applicable electrical codes must be followed during and after installation. All connections to be made by a qualified 

electrician.  

2.  Disconnect all power at the main circuit breaker before installing the PROZONE unit.  
3.  WARNING - To reduce the risk of injury, do not permit children to use this product unless they are closely supervised at all 

times.  

4. 

DANGER

 - Risk of electric shock.  

5.  Replace damaged cord immediately.  
6.  Do not bury cord.  
7.  Connect only to a properly grounded, grounding type receptacle.  
8.  Install at least 5 feet from the inside wall of the pool using non-metallic plumbing. The ozone generator is to be located one 

foot above the maximum water level to prevent water from contacting electrical equipment. Install to provide drainage of 
compartment for electrical components.  

9.  A pressure wire connector is provided in the control box inside the unit to permit connection of a minimum No. 8 AWG (8.4 

mm

2

) solid copper bonding conductor between this point and any metal equipment, metal enclosures of electrical 

equipment, metal water pipe, or conduit within 5 feet (1.5 m) of the unit as needed to comply with local requirements.  

10.  Wear safety glasses when drilling and tapping holes for installation of unit.  
11. 

WARNING

: Short term inhalation of high concentrations of ozone and long term inhalation of low concentrations of ozone 

can cause serious harmful physiological effects. Do not inhale ozone gas produced by this device.  

12.  Turn off power at source breaker before servicing the unit.  
13. 

SAVE THESE INSTRUCTIONS.

  

TABLE OF CONTENTS

 

 

Safety Instructions  

 

Introduction to Ozone  

 

Preparing for Installation  

 

Installation of PZ2 Series Ozonators  

 

Operation of PROZONE  

 

Prozone Operation  

 

Water Chemistry  

 

Troubleshooting Guide  

 

Installation Kit Inventory  

 
 
 
 
 
 
 
 
 

Summary of Contents for PZ2 Series

Page 1: ...level to prevent water from contacting electrical equipment Install to provide drainage of compartment for electrical components 9 A pressure wire connector is provided in the control box inside the u...

Page 2: ...e also provides some disinfection but an ozone residual cannot be established so the use of chlorine or bromine is always recommended PREPARING FOR INSTALLATION 1 Locate Model PZ2 1 or PZ2 2 Ozonators...

Page 3: ...solenoid control valve may be necessary 13 Attach one end of the remaining length of 1 4 inch hose to the ozone generator and the other end to the inlet side of the check valve Making sure flow is awa...

Page 4: ...lamp 4 Insert venturi injector into the other end of the 6 inch length of 1 inch hose making sure flow is away from the saddle and secure with a clamp Flow is marked on side of injector with an arrow...

Page 5: ...cal Installation System is 120 or 240 VAC 50 60 HZ Wire Prozone ozone generator system to circulation pump switch or timer Prozone system and circulation pump should be started simultaneously Use N E...

Page 6: ...re Verify check valve in venturi is operating properly Cloudy water foamy water scum Water chemistry out of balance Total Dissolved Solids TDS level too high Filter not working Check readings and bala...

Page 7: ...itting 1 inch FPT x 1 inch HB 2 each Hose Polybraid 3 8 inch 20 feet 6m Hose Clear Vinyl 1 inch 10 feet 3 05m Compressor 1 each Valve Check inch 1 each Clamp Hose Metal 1 5 inch 4 each Clamp Plastic B...

Reviews: