background image

Original Sewell Amp

50 Watt

100 Watt

Power usage

250 Watts

300 Watts

Pre Amp Tubes

3 each ECC83

Power Tubes*

2EA EL34

4EA EL34

Power Tube Option

2EA 6L6

4EA 6L6

* Power Tubes should be purchased as matched sets. Use only tubes in pairs or 

quads that are factory-matched. Failure to use matched tubes can lead to tube 

failure and amplifier damage or abnormal operation.

Main Fuses
100V 50Hz/60Hz

2A 250V Type 3AG

4A 250V Type 3AG

120V 60Hz

2A 250V Type 3AG

4A 250V Type 3AG

230V 50Hz

1.5A 250V Type 3AG 2.5A 250V Type 3AG

Filament Fuses

2 each 10A 250V Type 3AG

B+ Fuses

2 each 500mA 440V Type 3AG

Weight
Head

34 lbs (15.5kg)

40 lbs (18.2kg)

1x12 Combo

54 lbs (24.5kg)

N/A

2x12 Combo

62 lbs (28.2kg)

68 lbs (31kg)

Dimensions
Head

22.5in X 11in X 9.75in

22.5in X 11in X 

9.75in

1x12 Combo

22.5in X 20in X 

9.75in

N/A

2x12 Combo

26.5in X 21in X 

9.75in

26.5in X 21in X 

9.75in

Service Notes

Tubes

Tubes are consumables as they have a given usable lifespan.  They are part of the heart of 

the tone, so keeping correctly operating tubes is essential.  Tubes can fail catastrophically or 

gradually, and it’s good to know what to look for if they start to go bad.  Periodically inspect 

them and look to see if anything inside the tube is glowing cherry red other than the normal 

orange glow of the filament.  This would indicate a situation where the tube is conducting 

more current than it is capable of handling and most likely about to fail.  Two other conditions 

to observe are 1) filaments not glowing or 2) a miniature fireworks display inside the tube.  Any 

of the above conditions indicate serious problems with the tube and should be taken care of 

immediately. Tubes quite often are the cause of spurious noise in the amp.  Microphonic tubes 

will squeal or rattle with the vibrations of the cabinet.  If suspected, tap each tube lightly with 

a pencil with the amp powered up—the suspect tube will let you know.  Note that there is a 

normal metallic clinking when doing this, but a microphonic tube will be quite loud.

Instructions for Qualified Service Technician: To install the tubes, check that the power cord 

is not plugged in, then remove the wooden back panel with a screwdriver and notice the 

tube sockets. Note that the cooling fan may need to be unplugged from the chassis. Looking 

from the back, install the Power tubes (EL34, 6L6, etc.) in the left sockets.  In each case, align 

the center pin guide correctly with the socket, making sure that the pin guide key fits with 

the corresponding slot in the socket. The ECC83 preamp tubes can then be placed in the 

smaller 9-pin sockets to the right of the power tubes. Please refer to the tube chart inside 

the amplifier for proper tube locations.  Be aware of the pin alignment with these, as there is 

only one way they can fit.  We utilize tube sockets that allow relative ease of tube installation, 

but never force tubes into the sockets if there becomes a problem.  Also, never torque the 

tubes, only gently rock them from side to side during insertion or removal.  After preamp tube 

installation, place the cylindrical spring tension preamp tube covers over the tubes. Ensure 

the cooling fan is plugged back into the jack on the chassis. Failing to do so can create a safety 

hazard.

Replacing preamp tubes will not require any adjustment, but the power tubes will need 

rebiasing to assure proper operation.  After power tube replacement, initially inspect the 

tubes often to assure there are no “cherry red” components within the tube.  Tubes today can 

have a wide variety of tolerances, and a re-bias is highly recommended with new ones

Fuses

There are 5 fuses installed in the amplifier. Only 1 of these, the main input fuse, is accessible 

and replaceable by the user. There are 4 fuses internally for added safety. 2 of these fuses are 

high voltage fuses, and 2 fuses are for the lower filament voltages. In all cases, labels indicate 

the type and rating of the fuse. Replacement fuses MUST BE THE SAME TYPE AND RATING. If 

they are not you can permanently damage your amplifier. Please contact your local PRS dealer 

or the PRS accessories web site for information on ordering replacement fuses.

Instructions for Qualified Service Technician: Replacement of internal fuses requires removal 

of the back panel and removal of the chassis. First, ensure the power cord is not plugged in, 

then remove the back panel with a screwdriver. Turn the amplifier upside down and place on 

padded and safety-certified work surface. Loosen the 4 bolts holding the chassis to the top 

of the cabinet. The reverb pan may need to be removed before removing the chassis. Ensure 

the reverb cords are unplugged, and remove the hardware holding the reverb pan in place. 

Check that all components are cool so that burns do not occur. Then, by holding onto the 

transformers, lift the front of the amp so the front control is out the cabinet, and carefully 

pull the chassis out.

NOTE!

 Capacitors may retain an electric charge and can be dangerous even when the unit is 

off, unplugged, and has not been played for an extended period of time. USE CAUTION!!!!

Locate the fuse holders and remove them, and check for continuity. Blown fuses can indicate 

a failure condition and should be treated as though a problem exists. Check the label for the 

proper type and rating. After all fuses have been replaced and the amp is tested as acceptable 

and safe, reinstall the chassis by working in reverse. Be sure to replace the reverb pan and 

hardware, and plug the reverb cords back into place. Before installing the back panel, ensure 

the cooling fan cord is plugged into the proper jack.

Original Sewell Guitar Amplifier 

User’s Manual

Tech Specs

Reviews: