10. Repeat steps 8 and 9 to take measurements in at least three positions over at
least 70° of rotation. (Taking more position measurements improves the reliability
of results.)
11. When enough measurement points over at least 70° rotation have been taken,
press
q
then use
f
/
g
to highlight the context menu item ‘Stop’.
Confirm selection by pressing
e
to stop measurement.
7 .2 .5 Evaluation and alignment
Since offset does not affect the performance of cardan shafts, only angularity is
displayed for correction.
1. Press
k
to view alignment results.
Alternatively, stop
measurement by pressing
q
followed by
3
.
Summary of Contents for OPTALIGN smart RS5 BT