Configuration
163
8 .2 .3 Default settings
The “Default settings” screen is opened by highlighting the ‘Default settings’ icon use
the navigation keys then pressing
e
to confirm selection. Alternatively, pressing
3
while in the configuration screen to directly access the available settings. The screen is
used to set specific default parameters. The default changes are effective upon restart
or if a new file is created.
‘Default RPM’ – used to set the required default rpm. Use
f
/
g
and
highlight ‘Default RPM’ then use the data entry keys to enter the required
default rpm. Confirm entry by pressing either
e
or
ß
. Every new alignment
file created will then automatically be preconfigured with this RPM value already
entered.
‘Reference diameter’ – used to set the required reference diameter. Use
f
/
g
and highlight ‘Ref. diameter’ then use the data entry keys to enter
the required reference diameter. Confirm entry by pressing either
e
or
ß
.
Every new alignment file created will then automatically be configured with this
coupling diameter value already entered.
‘Default sensor’ – The system’s default sensor is the RS5 BT sensor. Depending
on the system configuration, the default sensor may be set to RS5 sensor or
ROTALIGN sensor or OPTALIGN sensor.
Summary of Contents for OPTALIGN smart RS5 BT
Page 10: ...OPTALIGN smart RS5 BT handbook 10 Page intentionally left blank ...
Page 16: ...OPTALIGN smart RS5 BT handbook 16 This page intentionally left blank ...
Page 28: ...OPTALIGN smart RS5 BT handbook 28 Page intentionally left blank ...
Page 38: ...OPTALIGN smart RS5 BT handbook 38 This page intentionally left blank ...
Page 112: ...OPTALIGN smart RS5 BT handbook 112 This page intentionally left blank ...
Page 174: ...OPTALIGN smart RS5 BT handbook 174 This page intentionally left blank ...
Page 194: ...OPTALIGN smart RS5 BT handbook 194 This page intentionally left blank ...