Use
f
/
g
to highlight the context menu item ‘Horizontal thermal growth’
then press
e
to confirm selection. The horizontal thermal growth view opens. Now
proceed to enter values as described for vertical orientation previously.
Press
ß
after entering all values.
Thermal growth values may be disenabled from the “Thermal growth” screen by
highlighting the tick [
] then confirming selection by pressing
e
.
Alternatively, press
q
while in the “Thermal growth” screen. The context menu
appears.
Carefully observe sign
convention (+ and -) when
entering thermal growth
values. Thermal growth
values are NOT a target;
instead they represent the
amount and direction of
the anticipated movement
that the machine will
undergo when put in
operation.
The editing box may also
be opened by highlight-
ing a foot value using
the navigation keys then
pressing
e
.