Horizontal shaft alignment
81
5 .11 .5 Alignment condition
The ‘smiley’ symbol on the coupling results screen indicates the degree to which
the measured alignment condition meets tolerances. The smiley face depicts either
alignment within tolerance or out of tolerance and appears only when tolerances
have been enabled (see section 5.7.4 ‘Coupling properties’).
The computer LED system provides additional information on the tolerance status.
Tolerance Smiley Lit LED
Within tolerance Happy face Blue
Within tolerance
OK
Green
Out of tolerance Sad face Amber
Worse tolerance Sad face Red
The ‘smiley’ TAKES INTO ACCOUNT any targets and thermal growth values
which you may have entered – see page 50 to page 57.
Within excellent tolerance
Within acceptable tolerance
Out of tolerance