2 .1 .4 Laser safety
OPTALIGN smart RS5 BT system uses the RS5 laser ALI 3.910. According to IEC 60825-
1:2007, RS5 laser is classified as a Class 2 laser product. The laser complies with 21
CFR 1040.10 and 1040.11 except for deviations pursuant to Laser Notice No. 50,
dated June 24, 2007. The laser operates at a wavelength of 630 – 680 nm and has a
maximum radiant power <1 mW. No maintenance is necessary to keep the product
compliant as outlined above.
Do not look directly into the laser beam at any time. (The natural blink
reaction of the human eye is normally sufficient to protect the eyes from
any dangers posed by looking at the laser beam briefly. But as natural blink
reaction may fail to occur, care should be taken to avoid staring into the
beam.)
Do not insert any optical devices into the beam path.
The LED on the front of the laser illuminates whenever the laser beam is
emitted.
CAUTION – Use of controls or adjustments or performance of procedures
other than those specified herein may result in hazardous radiation
exposure
2.2 Operating information
2 .2 .1 Temperature range
OPTALIGN smart RS5 BT and its related system components must be used at tempera-
tures between -10°C and 50°C (14°F to 122°F). Outside of this range, the specified
accuracy may not be maintained.
Store the system and its related components at temperatures between -20°C and
60°C (-4°F to 140°F).
2 .2 .2 Temperature effects and fluctuations
Powerful heat sources or steam located near the laser beam could influence the
accuracy of measurements as a result of beam deflection. In practice, however, this
effect occurs seldom at distances up to 1 m. If in doubt, the effect can be elimi-
nated by shielding the system from the heat/steam source during measurement and
adjustment.
As with all precision optical measurement devices, sudden fluctuations in tempera-
tures (e.g. resulting from sunlight), could result in erroneous measurements.
Allow adequate time for the system and its related components to reach the
ambient temperature.
s
WARNING
H
Note
Summary of Contents for OPTALIGN smart RS5 BT
Page 10: ...OPTALIGN smart RS5 BT handbook 10 Page intentionally left blank ...
Page 16: ...OPTALIGN smart RS5 BT handbook 16 This page intentionally left blank ...
Page 28: ...OPTALIGN smart RS5 BT handbook 28 Page intentionally left blank ...
Page 38: ...OPTALIGN smart RS5 BT handbook 38 This page intentionally left blank ...
Page 112: ...OPTALIGN smart RS5 BT handbook 112 This page intentionally left blank ...
Page 174: ...OPTALIGN smart RS5 BT handbook 174 This page intentionally left blank ...
Page 194: ...OPTALIGN smart RS5 BT handbook 194 This page intentionally left blank ...