3. With the sensor aperture open, press
m
and establish wireless communication
(refer to ‘Wireless measurement’ section 4.4’). The laser beam location should be
apparent in the adjustment screen.
4. Press
q
. A context menu appears. Use the context menu item ‘Measurement
mode’ to select the ‘Multipoint’ measurement mode. (For details about this
mode refer to ‘Multipoint measurement’ section 6.1.1.)
5. Press
e
to confirm selection.
6. The laser dot should be in the square target. If not, center laser beam (refer to
‘Laser beam adjustment’ in section 5.9).
7. With laser beam centered, press
e
to take the first measurement point.
8. Rotate the sensor to the next measurement point.
9. Rotate the laser holder and the RS5 laser and observe the detector view in the
measurement screen (see next screenshot): at the moment when the laser dot is
positioned on the Y-axis, press
e
to take the next measurement.
Note: The Multipoint
measurement mode is
an optional firmware
module. Please order
part number ALI 12.715
[Multipoint measure
mode] to activate the
feature.
Cardan drive machines
Summary of Contents for OPTALIGN smart RS5 BT
Page 10: ...OPTALIGN smart RS5 BT handbook 10 Page intentionally left blank ...
Page 16: ...OPTALIGN smart RS5 BT handbook 16 This page intentionally left blank ...
Page 28: ...OPTALIGN smart RS5 BT handbook 28 Page intentionally left blank ...
Page 38: ...OPTALIGN smart RS5 BT handbook 38 This page intentionally left blank ...
Page 112: ...OPTALIGN smart RS5 BT handbook 112 This page intentionally left blank ...
Page 174: ...OPTALIGN smart RS5 BT handbook 174 This page intentionally left blank ...
Page 194: ...OPTALIGN smart RS5 BT handbook 194 This page intentionally left blank ...