Horizontal shaft alignment
77
If no in-house standards or specifications from the coupling or machine manufacturer
are available, the computer alignment condition LEDs and the smiley provides a
tolerance check based on standard industry norms. If the measured alignment falls
within acceptable tolerance, the green LED lights up. The blue LED lights up when
the measured alignment falls within excellent tolerance. The red or yellow LED lights
up when alignment is out of tolerance. In this case, the machines must be aligned.
If the coupling results show that misalignment exceeds the tolerance, then the
machine must be realigned by shimming vertically and repositioning the machine
horizontally. The different views may be accessed by pressing
k
/
f
/
g
.
In this example, the left
machine has
no fixation
therefore its foot values are
not displayed.
In this example, the left
machine is stationary but
has
two feet fixation
. The
highlight is at both front
feet. The corresponding
foot value in this case is
0.00 mm.