6-25
ROTALIGN 01.2000
Soft foot examples
The following notation is used for these examples:
◆
The feet are shown oversize outside of the machine outline.
◆
ROTALIGN readings are outside the feet.
◆
Feeler gauge readings are inside the feet.
◆
Blank spaces mean the reading is not available.
◆
Feet are named clockwise A to D
For maximum accuracy during soft foot measurement (and espe-
cially when coupling play is present), the shafts should be rotated
so that the sensors are oriented vertically (12:00 - 6:00 direction).
Example 1
Advanced diagnosis & correction of soft foot
0
44444
44444
44444
00000
100
100
100
100
100
88
88
88
88
88
88
88
88
88
88
92
92
92
92
92
88
88
88
88
88
00000
00000
84
84
84
84
84
00000
80
4
76
Foot notation
clockwise A - D
ROTALIGN Soft foot
readings
Feeler gauge readings
ROTALIGN readings show near perfect rock, tempting the inexperi-
enced aligner to shim feet B and D. In this case, that would be a
mistake. The 4/100 mm difference diagonally, with near zero read-
ings on the other diagonal, prompts feeler gauge examination of feet
B and D. The feeler gauge results show very similar average gaps
between feet B and D, but one is plainly sloped while the other is
nearly flat.
Conclusion: shim only foot D 88/100 mm and recheck all four feet.
C
D
A
B
F
Note
Summary of Contents for ROTALIGN ALI 3.500
Page 13: ...1 10 ROTALIGN 01 2000 This page intentionally left blank ...
Page 103: ...4 66 ROTALIGN 01 2000 This page intentionally left blank ...
Page 121: ...5 18 ROTALIGN 01 2000 This page intentionally left blank ...
Page 143: ...6 22 ROTALIGN 01 2000 This page has intentionally been left blank ...
Page 158: ...6 37 ROTALIGN 01 2000 This page intentionally left blank ...