153
6. With the laser beam centered, and the needle exactly at the center of the green
sector, press
e
to take the first measurement.
7. Rotate sensALIGN sensor to the next measurement position.
8. Turn the laser-side shaft and observe the on-screen needle indicator. The ‘Take
point’ button only appears when the needle is in the blue sector.
9. Press
e
to take the next measurement.
10. Repeat steps 7–9 above, to take measurements in as many positions over as
wide an angle as possible, ensuring that the measurement quality is acceptable.
11. When a good enough measurement quality has been attained, stop
measurement using the “Measurement screen” context menu item ‘Stop’.
The ‘Take point’ button
appears only when the laser
beam strikes the sensor
within the detector range,
and the value stabilization
time is attained.