ROTALIGN Ultra iS Shaft handbook
46
Thermal growth values can be entered only when the type of mounting is either
machine feet or bearing or V-shaped support, and ‘Thermal growth’ enabled. To enter
thermal growth values press
q
while in the “Machine type” screen. The context
menu appears.
Press
2
to access the thermal growth screen. Alternatively, use either
f
/
g
to highlight ‘Thermal growth’, confirming selection by pressing
e
.
Use
h
/
i
to cycle through the feet positions, highlighting the value boxes. When a
value box is highlighted, enter thermal growth value directly using the data entry keys.
Confirm entry by pressing either
e
or
ß
.
Thermal growth values are
activated when the ‘thermal
growth enabled’ box is
checked.
Thermal growth values may
be entered directly using the
data entry keys.