72
4.14.3 Horizontal and vertical live MOVE
The alignment corrections involving shimming and the lateral positioning of the
machines can be followed in a real-time interactive display. From the results screen,
press
q
. The context menu appears. Use
f
/
g
to highlight ‘Move’.
Press
e
to confirm selection and start live Move.
If the laser beam is centered proceed to carry out live horizontal and vertical Move.
If however the laser beam is not centered, use the “Move measurement” screen
context menu item ‘XY view’ (see section 5.2.7) to center the laser beam then
press
ß
to go back to the results screen to proceed with live Move.
Live Move may be stopped via the “Move measurement” screen context menu item
‘Stop’. Use
f
/
g
to highlight the menu item ‘Stop’ then confirm selection by
pressing
e
.
Live horizontal and vertical
Move can be monitored
simultaneously. Move is
carried out in one direction
(say vertical shimming first)
then in the other direction
(say horizontal Move).
Note that if the machines
can be accessed from
both sides, then the sub
menu item ‘Rotate view’
[‘View’ -> ‘Rotate view’]
may be used to change
the orientation of the
machines on the display
screen. For details refer
to section 4.12.1.5 ‘Rotate
view’.
Note
If however the laser beam is not centered, use the “Move measurement” screen
context menu item ‘XY view’ (see section 5.2.7) to center the laser beam then
press
ß
to go back to the results screen to proceed with live Move.
Summary of Contents for ROTALIGN Ultra iS
Page 1: ...ROTALIGN Ultra iS Operating handbook Shaft alignment...
Page 11: ...ROTALIGN Ultra iS Shaft handbook 10 This page intentionally left blank...
Page 56: ...55 Horizontal shaft alignment 1 2 4 5 6...
Page 123: ...ROTALIGN Ultra iS Shaft handbook 122 Page intentionally left blank...
Page 141: ...ROTALIGN Ultra iS Shaft handbook 140 This page intentionally left blank...
Page 177: ...ROTALIGN Ultra iS Shaft handbook 176 Page intentionally left blank...
Page 207: ...ROTALIGN Ultra iS Shaft handbook 206 Page intentionally left blank...
Page 213: ...ROTALIGN Ultra iS Shaft handbook 212 Declaration of conformity...