73
ROTALIGN Ultra iS monitors both horizontal and vertical Live Move concurrently.
If the results view is zoomed to the vertical view when the Move function is
started, only the vertical condition will be displayed (although both planes are
being monitored simultaneously). Likewise, if the results view is zoomed to the
horizontal view when the Move function is started, only the horizontal condition
will be displayed (but both planes monitored simultaneously). If the view is set
to both vertical and horizontal (as illustrated above) then both conditions will be
displayed. This information is recorded in the measurement table.
4.14.4 Shimming
i) Prepare the machines for shimming by ensuring the following:
The foot bolts are clean, intact and removable
Soft foot has been eliminated
The feet have enough shims under them should lowering the machine be
necessary.
Good quality shims such as PERMABLOC, MYLAR or LAMIBLOC are available
from PRÜFTECHNIK Alignment Systems
ii) Loosen foot bolts while avoiding to move the machine horizontally. If any foot
comes off the ground when loosened, suspect soft foot.
iii) Use the vertical foot correction values to shim BOTH front and back feet as
required. Positive feet values indicate that the feet are high and therefore shims
should be removed, while negative feet values indicate that the feet are low and
suggest addition of shim thickness.
Note that the “Move
measurement” screen
context menu item
‘Averaging’ may be used to
set the number of readings
to be averaged.
The context menu item
‘Extend’ may be used
to broaden the laser
beam detection range
measurement range.
The features ‘Extend’ and
‘Averaging’ are described
in sections 5.2.6 and 5.2.9
respectively.
Note
ROTALIGN Ultra iS monitors both horizontal and vertical Live Move concurrently.
If the results view is zoomed to the vertical view when the Move function is
started, only the vertical condition will be displayed (although both planes are
being monitored simultaneously). Likewise, if the results view is zoomed to the
horizontal view when the Move function is started, only the horizontal condition
will be displayed (but both planes monitored simultaneously). If the view is set
to both vertical and horizontal (as illustrated above) then both conditions will be
displayed. This information is recorded in the measurement table.
Horizontal shaft alignment
Summary of Contents for ROTALIGN Ultra iS
Page 1: ...ROTALIGN Ultra iS Operating handbook Shaft alignment...
Page 11: ...ROTALIGN Ultra iS Shaft handbook 10 This page intentionally left blank...
Page 56: ...55 Horizontal shaft alignment 1 2 4 5 6...
Page 123: ...ROTALIGN Ultra iS Shaft handbook 122 Page intentionally left blank...
Page 141: ...ROTALIGN Ultra iS Shaft handbook 140 This page intentionally left blank...
Page 177: ...ROTALIGN Ultra iS Shaft handbook 176 Page intentionally left blank...
Page 207: ...ROTALIGN Ultra iS Shaft handbook 206 Page intentionally left blank...
Page 213: ...ROTALIGN Ultra iS Shaft handbook 212 Declaration of conformity...