ROTALIGN Ultra iS Shaft handbook
84
The “Measurement mode” screen may also be used to set up the following
measurement properties:
Type of Sweep mode to be used – this can be either ‘IntelliSWEEP’ or the
customary ‘SWEEP’ method.
The duration in which readings are to be averaged – the longer the duration of
the averaging, the higher the number of readings collected. This feature applies
to ‘point’ measurements such as ‘IntelliPOINT’, ‘Multipoint’ and ‘Static mode’.
Measurement factor – this is expressed as either ‘Quality’ or ‘Standard Deviation’
(SD)
Dial indicator set-up used – these include ‘Rim and Face’ and ‘Reverse Indicator’
configurations.
5.1.1 IntelliSWEEP
IntelliSWEEP is a measurement method that actively
assists the user by automatically detecting errors and
providing guidance on how to avoid such errors. The method also eliminates error
influences such as coupling backlash, machine rotational angle and environmental
vibration, resulting in extremely precise measurement results. The method is used to
measure all standard machines.
Other IntelliSWEEP features include:
Intelligent filtering and averaging of results – this leads to high data reduction
without loss in measurement accuracy
Detection and elimination of coupling backlash and friction resulting from
abrupt starts and stops during shaft rotation
Monitoring both shaft rotational speed and direction during measurement
Providing real time quality values during measurement
Monitoring and measuring machine train vibration
Use
f
/
g
to select
the required measurement
property then press
e
to display the drop down
menu. Use
f
/
g
to
highlight desired property
then confirm selection
by pressing
e
. Exit the
measurement property box
by pressing
h
.
The measurement
properties appearing on
the right side of the screen
are measurement mode
dependent. To set the
properties for any particular
measurement mode, press
i
with the particular
measurement mode
highlighted. The cursor box
moves as shown opposite
to enclose the related
measurement properties.
Summary of Contents for ROTALIGN Ultra iS
Page 1: ...ROTALIGN Ultra iS Operating handbook Shaft alignment...
Page 11: ...ROTALIGN Ultra iS Shaft handbook 10 This page intentionally left blank...
Page 56: ...55 Horizontal shaft alignment 1 2 4 5 6...
Page 123: ...ROTALIGN Ultra iS Shaft handbook 122 Page intentionally left blank...
Page 141: ...ROTALIGN Ultra iS Shaft handbook 140 This page intentionally left blank...
Page 177: ...ROTALIGN Ultra iS Shaft handbook 176 Page intentionally left blank...
Page 207: ...ROTALIGN Ultra iS Shaft handbook 206 Page intentionally left blank...
Page 213: ...ROTALIGN Ultra iS Shaft handbook 212 Declaration of conformity...