ROTALIGN Ultra iS Shaft handbook
90
5.1.4.2 IntelliPOINT
IntelliPOINT is used in cases where the uncoupled shafts can be stopped at definite
positions. It is also used in cases where the shafts are coupled but torsional play exists.
This mode ensures that measurement points remain on the same rotational arc hence
increasing accuracy.
In this mode, the shaft supporting the laser is rotated to the position where the laser
beam strikes the center of the sensor lens. Measurement is taken when the laser
beam strikes the center of the detector.
After centering the laser beam as described in section 4.10, the ‘Take point’ button
appears on the screen.
With the ‘Take point’ button highlighted, press
e
to initiate the measurement arc by taking first
measurement point.
Note that in the initial
Intellipoint measurement
screen, the ‘Take point’
button appears on the
display when the laser beam
is centered. The on-screen
needle indicator provides
additional help in adjusting
the laser beam. The laser
beam should be initially
centered such that the
needle rests in the central
green sector.
Summary of Contents for ROTALIGN Ultra iS
Page 1: ...ROTALIGN Ultra iS Operating handbook Shaft alignment...
Page 11: ...ROTALIGN Ultra iS Shaft handbook 10 This page intentionally left blank...
Page 56: ...55 Horizontal shaft alignment 1 2 4 5 6...
Page 123: ...ROTALIGN Ultra iS Shaft handbook 122 Page intentionally left blank...
Page 141: ...ROTALIGN Ultra iS Shaft handbook 140 This page intentionally left blank...
Page 177: ...ROTALIGN Ultra iS Shaft handbook 176 Page intentionally left blank...
Page 207: ...ROTALIGN Ultra iS Shaft handbook 206 Page intentionally left blank...
Page 213: ...ROTALIGN Ultra iS Shaft handbook 212 Declaration of conformity...