ROTALIGN Ultra iS Shaft handbook
94
6. Proceed to enter the dial gauge reading directly using the data entry keys.
Confirm entry by pressing either
e
or
ß
. The next empty entry box is
highlighted. You may use the navigation keys to cycle through the value entry
boxes.
7. To view ROTALIGN Ultra iS Shaft gap and offset coupling values, press
q
, then
use
f
/
g
to highlight the context menu item ‘Stop’.
8. Confirm selection by pressing
e
. Coupling results are displayed.
Summary of Contents for ROTALIGN Ultra iS
Page 1: ...ROTALIGN Ultra iS Operating handbook Shaft alignment...
Page 11: ...ROTALIGN Ultra iS Shaft handbook 10 This page intentionally left blank...
Page 56: ...55 Horizontal shaft alignment 1 2 4 5 6...
Page 123: ...ROTALIGN Ultra iS Shaft handbook 122 Page intentionally left blank...
Page 141: ...ROTALIGN Ultra iS Shaft handbook 140 This page intentionally left blank...
Page 177: ...ROTALIGN Ultra iS Shaft handbook 176 Page intentionally left blank...
Page 207: ...ROTALIGN Ultra iS Shaft handbook 206 Page intentionally left blank...
Page 213: ...ROTALIGN Ultra iS Shaft handbook 212 Declaration of conformity...