Treble Check that everything has been installed correctly.
6.
W
ith the mains disconnected,
use a multimeter to measure the resistance
between the positive and negative terminals and ensure there is no short.
7. Plug in the mains and switch on.
8. Using a multimeter, verify the 5V output of the Pi converter is within the range
4.9 to 5.1V.
9.
Switch off the mains
and leave for 60 seconds.
10. Decide whether you will be connecting to the Einsy board by GPIO or by USB.
11. Fit the appropriate Pi Connection guide over the connector pins, so that only the
pins required are exposed.
Note: There are two different connection guides: One exposes the power, fan and
reset connections; and the other also exposes the GPIO pins required to connect to
the Einsy board.
Note: The connection guides have all of the ground pins marked with a tab to aid
identification.
- 20 -
Ground Pin Tags