The original MultiWave function on P5 and P10 Power Plants is the same as Variable MultiWave 
strength level four. Strength levels one through three are lower strength waves while strength levels 
five and six are the highest strength levels of MultiWave ever offered.

Try different MultiWave strength levels to suit your system's needs for best sound.

Considerations: Variable MultiWave strength levels five and six require more energy to be delivered 
from the regenerator in the Power Plant than the present single MultiWave selection does. If your 
Power Plant is already close to maximum power output or is working hard to make up for low input 
voltage, you may notice an increase in output distortion of the Power Plant when using Variable 
MultiWave setting five and six. It is recommended, in these cases, to stay with Variable MultiWave 
strength four or below to help maintain low output distortion to your equipment.

Phase Tune: Phase tune adjusts the time relationship (phase) between the incoming voltage 
waveform and the regenerated waveform. There are a few places that have unusual distortion which 
includes a very substantial time lag (phase shift) relative to the fundamental. In these situations the 
default setting of the Power Plant didn't perform as well as it could. 99% of the time, the default 
setting (0) is appropriate and no adjustment is necessary. If your Power Plant is consistently 
delivering less than 0.5% distortion (THD) in Sine mode, you should not need to make any 
adjustments. Below are the conditions under which you might want to adjust this setting:

1) Your power from the utility has extremely high distortion, over about 8%.
2) Your power from the utility is typically more than 10V (15V for 230V models) away from 
your desired output setting.
3) Your Power Plant is not able to reduce the incoming distortion by a factor of 10.

In other words, if your THD In reading is 8.0%, and your THD Out is 0.5%, your Power Plant is 
performing well. If your THD Out reading is 1.0% you may benefit from adjusting the Phase Tune. 
Please keep in mind that the Power Plant is correcting both THD and voltage errors. If your incoming 
voltage is within a few volts of the output setting, your Power Plant will be able to devote most of 
its capability to correcting the distortion. If the voltage is 10 volts or more away from the setting, the 
Power Plant is not going to be able to correct the THD as well. So if your utility voltage is more than 
10V off, and you are seeing your THD reduced by only a factor of 5, this is probably normal.
The procedure for setting the Phase Tune is simple. Experiment with different Phase Tune settings 
and see what setting gives you the lowest output THD reading. The optimum setting depends on 

how much distortion is on your power 
and what it looks like. Unfortunately 
there is no way to predict what it will be.

Setting Individual Zone Parameters: Each 
of the four Zones (labeled A, B, C, and 
D) can be independently controlled for 
sequenced power-cycling combinations.

Screen #2, #3, #4, and #5: INDIVIDUAL 
ZONE PARAMETERS — By touching the 
Next screen from the GENERAL SETUP 
menu, one will enter the controlling 

7

Summary of Contents for PerfectWave Power Plant 5

Page 1: ...Plant 5 0 6 7 4826 Sterling Drive Boulder CO 80301 15 059 01 1 PH 720 406 8946 support psaudio com www psaudio com Rev B 2010 PS Audio International Inc All rights reserved Owner s Reference Instructi...

Page 2: ...arted Quick Start Guide Power down First Zones How to Turn it on Home Screen Scope Reading input output vitals and status information Setup Voltage regulation Mode Setting and Setting Individual Zone...

Page 3: ...pin on the end of the AC cord All PS products ship with a grounding type plug If the provided plug does not fit into your outlet consult an electrician for replacement of the obsolete outlet Protect t...

Page 4: ...mentary output capabilities of up to 1200 Volt Amps All Power Plant 5 s labeled EX GR or UK can output a continuous load of up to 1200 Volt Amps of pure regulated AC with peak momentary output capabil...

Page 5: ...ing unadulterated AC into your system it is not going to provide pinnacle performance Choosing any PerfectWave AC Power Cable and or an upgraded receptacle will affect significant performance improvem...

Page 6: ...P5 powered down Power zones should be used to isolate different genres of equipment from each other For instance you can group digital equipment together on a single zone and multiple analog sources...

Page 7: ...onnection one will see either a red or green colored globe symbol based on whether or not the unit is connected to the network via Ethernet cable A valid connection to the router must be established t...

Page 8: ...which lessens the quality of musical playback and weakens the performance of your system By completely eliminating the original AC signal and applying a reference sine wave using a sine wave generato...

Page 9: ...this setting you may notice the output THD climb slightly higher As general guidelines tube equipment and electrostatic speakers will benefit from the High Regulation setting whereas solid state ampl...

Page 10: ...t is necessary If your Power Plant is consistently delivering less than 0 5 distortion THD in Sine mode you should not need to make any adjustments Below are the conditions under which you might want...

Page 11: ...th no delay and power down with a three second delay 2 DELAYED As the front panel power button is engaged any zone set to DELAYED will power up with a three second delay and power down with a zero sec...

Page 12: ...ecommended to activate Cleanwave while you are listening as it may not sound correct until the Cleanwave cycle has finished The option exists for a 10 second or a 60 Cleanwave cycle by touching the Ad...

Page 13: ...ne must first power down the PerfectWave P5 using the back panel power switch One must then reapply AC power to the PerfectWave P5 by flipping the back panel power switch to the On position The unit w...

Page 14: ...products purchased from PS Audio or its authorized dealers and agents What Will PS Audio Do to Correct the Problem In the event your product fails your sole remedy under this limited warranty shall b...

Page 15: ...or unauthorized repair including repairs not authorized by PS Audio Fire lightning flood acts of God or other contingencies beyond the control of PS Audio Products purchased through an unauthorized s...

Page 16: ...g the product to PS Audio You should insure the product for its full retail cost in the event it gets lost or damaged in transit PS Audio is not responsible for damage incurred in products sent to us...

Page 17: ...reserved Owner s Reference PerfectWave Power Plant 5 0 6 7 Service 4826 Sterling Drive Boulder CO 80301 15 059 01 1 PH 720 406 8946 support psaudio com www psaudio com Rev B Date of Purchase Your Seri...

Page 18: ...All rights reserved Owner s Reference PerfectWave Power Plant 5 0 6 7 Notes 4826 Sterling Drive Boulder CO 80301 15 059 01 1 PH 720 406 8946 support psaudio com www psaudio com Rev B 2010 PS Audio In...

Reviews: