PS Engineering Inc. ®
PAR200A Audio Selector Panel, COM radio Controller and Intercom System
Installation and Operator’s Manual
200-228-0200
Page 3-4
Rev. 4, DEC. 2017
4.
Turn the small knob to select the location (1 through 5).
5.
Push the small knob again, and the display will revert, and the frequency is stored in that location.
NOTE: If you do not push the small knob, the frequency will not be stored, and reverts to
STBY
.
To recall stored frequencies:
1.
Press and Hold the
C2
button until the display changes to
FREQ
RECALL
.
2.
Using the small knob, select the desired location in
MEM
field.
3.
Push the small knob to accept this as
STBY
frequency
. NOTE: If you do not push the small knob,
the frequency will not change to the stored, and reverts to
STBY
.
Figure 3-5 Frequency Recall
3.7.2
Radio Squelch
To defeat the automatic radio squelch, push and hold the frequency knob until the display changes to
ASQ
OFF
, which defeats the squelch and you will hear any weak signals.
Press the right hand side rotary selector knob again until you get the
ASQ ON
, to restore the Automatic
Squelch.
Figure 3-6 Radio Squelch on/off
3.7.3
Monitor Mode (when PAR200A is COM 1 or stand-alone only)
If the TY91/92 is interfaced as a standalone COM or as COM 1, the radio’s standby frequency monitor can
be used. To activate the monitor mode, press and hold the
N1
button until “
MON
” appears in the display.
PAR200A
PAR200A
Figure 3-4 Frequency storage