WIL-11050-E-05
Wilden
®
11
PERFORMANCE
P100 PLASTIC
PTFE-FITTED
Ship Weight ..... Polypropylene 4 kg (8 lbs)
PVDF 5 kg (10 lbs)
Air Inlet .................................. 6 mm (1/4")
Inlet ...................................... 13 mm (1/2")
Outlet ................................... 13 mm (1/2")
Suction Lift
4.5 m Dry (14.7')
9.3 m Wet (30.6')
Disp. Per Stroke
1
........... 0.10 l (0.027 gal.)
Max. Flow Rate ......... 57.0 lpm (15.0 gpm)
Max. Size Solids ................ 1.6 mm (1/16")
1
Displacement per stroke was calculated
at 4.8 bar (70 psig) air inlet pressure against
a 2 bar (30 psig) head pressure.
Example:
To pump 20.8 lpm (5.5 gpm)
against a discharge head pressure of
1.4 bar (20 psig) requires 2.8 bar (40 psig)
and 13.6 Nm
3
/h (8 scfm) air consumption.
(See dot on chart.).
Caution: Do not exceed 8.6 bar (125 psig)
air supply pressure.
Flow rates indicated on chart were determined by pumping water.
For optimum life and performance, pumps should be specified so that daily
operation parameters will fall in the center of the pump performance curve.