23
NOTE:
It is recommended to install an outside air inlet with a diameter of at least 5 inches in the room where the heating
appliance is installed (see drawing below). It is preferable to choose a wall which is not exposed to dominant winds,
depending on the conditions surrounding your house. In order to avoid condensation, the pipe should be insulated
and its total length should be at least 10 feet.
Insulated pipe (full length)
Exterior
Fresh air
intake
Free air
entry
P-trap
2.7
COLD AIR DUCTING SUPPORT INSTALLATION
Your furnace must be equipped with a cold air ducting support. You will find this part in the hopper when the product
is delivered. The cold air ducting support can be installed at the left, at the right or behind the blower of the furnace.
The cold air ducting support is secured using 6 screws supplied with the owner’s manual.