12.4. PIPE CONNECTOR AND DAMPER
The Max Caddy Add-on must be connected to a duct system and chimney that are in good condition and suitable for
wood burning. the use of a 6" connecting pipe and chimney is recommended.
It is strictly forbidden to connect a
solid fuel burning appliance to a chimney already connected to a propane or natural gas appliance. Regulation
CAN/CSA B365.1
12.5. ELECTRICAL CONNECTIONS
See Section 15.11 - ELECTRICAL CONNECTIONS
12.6. SERVOMOTOR INSTALLATION
See Section 14.5 SERVOMOTOR INSTALLATION AND CONNECTION
THERMOSTAT INSTALLATION
12.7. OPERATING INSTRUCTIONS
Operate the existing furnace periodically to ensure that it will operate satisfactorily when needed.
On the wood add-on, the thermostat controls the air inlet damper. When the thermostat calls for heat, the damper
opens and the combustion is stirred up. When the add-on gets hot enough, the RTD probe activates the blower motor
of the existing furnace at the speed selected for wood heating.
When there is no call for heat, the air inlet damper must be completely closed and the chain must be affixed to the
damper motor at the “8 o’clock” position.