6
3. GENERAL FEATURES
Maximum log length
25 in (635 mm)
/ north-south*
Diameter of the flue collar
6 in (152 mm)
Recommended chimney diameter
6 in (152 mm)
Required type of chimney
CAN/ULC S629 (2100 °F)
Baffle material
C-Cast
Alcove installation
Not approved
Mobile home installation
‡
Not approved
Appliance weight (without option)
614 lb (279 kg)
Shipping weight (without option)
729 lb (331 kg)
Particulate emission standard
CSA B415.1-10
Canadian standard (safety)
CSA B366.1
** East-west: through the door you see the longitudinal sides of the logs; north-south: through the door you see the tips of the logs.
‡
Mobile home (Canada). In Canada, a mobile home is a dwelling for which the manufacture and assembly of each component is
completed or substantially completed prior to being moved to a site for installation on a foundation and connection to service
facilities and which conforms to the CAN/CSA-Z240 MH standard.
4. SPECIFICATIONS
Color
Grey
Thermostatic control
Yes
Door type
Single, glass with cast iron frame
Glass type
Ceramic glass
Hot air plenum
– dimensions (Depth or Height)
32 1/8 in
Hot air plenum
– dimension (Width)
25 3/8 in
Ash pan
– dimensions (Width x Depth x Height)
11 15/16 in x 19 5/8 in x 2 5/8 in
Clearance
– front
48 in
Clearance
– back wall
12 in
Clearance
– side wall
6 in
Clearance
– opposite side wall
24 in recommended service clearance
Clearances
– ducts
6 in for the first 6 feet with heat shield and 1 in after
Fresh air intake adapter option
5 in
Fresh air intake adapter
– connection location
Left or right
Fresh air intake adapter
– connecting pipe diameter
6 in
Tested and listed as per applicable standards
By an accredited laboratory (CAN)
Warranty
Limited lifetime