52
SERVICE
Before calling for service, first check the following
- Fuel
supply
- Electric
fuses or breakers
- Thermostat
setting
-
PC board settings
-
The state of the green diagnostic LED on the burner control.
MAINTENANCE
WARNING:
Turn off electric power supply before servicing the unit.
1. The furnace, the burner and the flue pipe should be cleaned at least once a year.
2. The nozzle should be inspected and replaced if needed. Handle with care to avoid damaging its surface.
3. The electrodes should be adjusted as indicated in the burner manual.
4. Lubricate the burner motor bearings twice a year. (2 or 3 drops of SAE 20 non detergent lubricating oil).
5. The oil filter should be verified annually and replaced if needed.
FILTERS
The furnace should never be operated without filters.
This applies especially to temporary heating during construction period. Operating the furnace without filters would
allow dust and other particles in the air to circulate freely and to penetrate into the fan and motor carters, causing some
defects. Clean and replace filters as often as required.
Note : The operation cost is higher when using a dirty filter.
7- ELECTRICAL DIAGRAMS
Refer to SECTION A of this manual.
NOTES:
______________________________________________________________________________________
______________________________________________________________________________________
______________________________________________________________________________________
______________________________________________________________________________________
______________________________________________________________________________________
______________________________________________________________________________________
______________________________________________________________________________________
______________________________________________________________________________________
______________________________________________________________________________________
______________________________________________________________________________________
Burner no.: _______________ Model: _____________ Date of installation: _________________
Service telephone no.: Day: ______________________ Night: ___________________________
Dealer’s name and address: _______________________________________________________
TEST REPORT :
CO
2
_______% Temp. at stack: ______________ Draft at stack: ________IN.W.C.
Nozzle output: _______________GPH Smoke colour: ______________________
Inspected by : _______________________________________________________