34
11.3.2. LANGUAGE SELECTION AND TEMPERATURE UNIT
To choose the language and temperature unit, press the "Settings" button. In the "Main" menu, choose "SETUP" and
then "GENERAL". Choose the preferred language and temperature unit.
11.4. ADDING AUXILIARY HEATING SOURCE AND SELECTION OF OPTIONS
To add an auxiliary source of heating or to add options to your furnace, press the "Settings" button. On the “MAIN”
page, choose “SETUP” and “OPTIONS”.
By default, no auxiliary source of heating or options are selected. To select an option, simply press the white square to
the left of the desired option. When an option is chosen, the selected square turns green.
To confirm the selection of your options, press the button '' SAVE + EXIT ''. This step takes you to a list of questions
about your selections that are essential for their good functioning.
11.4.1. TRANSITION TO AN AUXILIARY HEAT SOURCE
When there is a demand for heat, the furnace checks the temperature in the plenum. If the temperature is beyond the
KIP, the fan will turn on. If the temperature is below the KIP, the furnace will wait the "Rise Time" delay and check the
temperature again in the plenum. If the temperature in the plenum goes up 20°F but has not reached the KIP, the
furnace will wait for additional time ("KIP Time") and recheck the temperature in the plenum. If the temperature has not
reached the KIP, the auxiliary heating will start. The icon "Wood" will turn yellow and the auxiliary heat icon will turn
green.
For the electrical element and/or the oil unit, the fan starts as soon as the thermostat asks for heat. In other words, for
safety reasons, the fan does not wait for the hot air plenum to reach a predetermined minimum temperature.
The furnace remembers what heating source was used in the last request of the thermostat. If the last heating demand
was met by the auxiliary heater, the furnace automatically start this one.
To restart the furnace using the wood mode, go on the touch screen on the main page and press on the wood icon.
The icon will become green and the auxiliary heating source icon will become yellow.
11.4.2. TRANSITION SETTINGS
It is possible to slightly adjust the transition settings from the wood option to the auxiliary source of heating. To do this,
go to the "MAIN" page on the touch screen under the "SETUP" option and choose "WOOD SETUP ". On this page,
you can change the KIP, KOP, the Rise Time and KIP Time.
KIP (Kick-In point): Temperature of the plenum where the fan turns on.
KOP (Kick-Out point): Temperature of the plenum when the fan stops.
Rise Time: Time allowed for plenum temperature to increase by 20 ° F.
KIP Time: Additional time allowed to reach the KIP when the Rise Time ended with an increase of 20°F.
Summary of Contents for MAX CADDY PF01102
Page 10: ...10...
Page 47: ...47 15 GENERAL ELECTRICAL DIAGRAM...
Page 48: ...48 16 ELECTRICAL DIAGRAM FOR PARALLEL FURNACE...
Page 49: ...49 17 ELECTRICAL DIAGRAM FOR ELECTRIC UNIT...
Page 55: ...55 22 7 DIFFERENT INSTALLATION...
Page 61: ...61 26 ELECTRICAL DIAGRAM BECKETT OIL UNIT...
Page 62: ...62 27 ELECTRICAL DIAGRAM RIELLO OIL UNIT...
Page 64: ...64 28 4 24V ADDITIONNAL EQUIPMENT 28 5 AIR CONDITIONNING DAMPER 28 6 HUMIDIFIER...
Page 65: ...65 28 7 HEAT PUMP 29 EXPLODED VIEW AND PART LIST...
Page 66: ...66...
Page 67: ...67...
Page 68: ...68...
Page 69: ...69...
Page 70: ...70...
Page 71: ...71...
Page 72: ...72...