28
MINI-CADDY ADD-ON
3.1.16 INSTALLATION WITH AN EXISTING OIL FURNACE
Note:
the fan limit control PA08522 (1) is not provided with the furnace and has
to be purchased separately.
To install the fan limit control assembly (1) (PA08522 not included with the
furnace), remove the cover on the fan limit control and the cover on the junction
box. Slide the fan limit control’s probe in the opening (2) provided for that
purpose next to the flue outlet on the back of the furnace. Secure the fan limit
control and junction box with screws (not supplied) in the holes intended for that
purpose. Once the wiring as per
Appendix 1
is
completed, put the covers back
on.
2