52
In the event of a chimney fire, first call your local fire department and water
the roof in the vicinity of the chimney.
Make sure that the furnace door and the air intake damper are closed (if need be,
lower the thermostat setting or unhook the air intake damper connecting rod).
CLOSE the barometric draft damper manually if one is installed.
In the event of uncontrollable fire (caused by wrongful operation or excessive
chimney draft), follow the same procedure as in a chimney fire but you must then
OPEN the barometric draft damper manually if one is installed.
4.7 LOCAL FIRE DEPARTMENT.
Telephone: ___________________________________
4.8 PROLONGED POWER OUTAGE
To reduce the risk of overheating during a prolonged power outage (more than
10 minutes), it is recommended to:
Make certain that the air intake damper is closed.
Open the blower access panel and remove the air filter to improve the
circulation of air around the combustion chamber through natural convection.