background image

P50 Apartment Compactor 

 

PSI Waste Equipment Services, Inc. 

Sec

Ɵ

on 1, Safety and Responsibili

Ɵ

es 

 

Safety Decals 

 

Replacement

 

decals

 

are

 

available

 

upon

 

request.

 

Part

 

#

 

Descrip on

 

Qty

 

300004

 

Cau on

 

Door

 

Closed

 

4

 

300005

 

Cau on

 

Federal

 

Law

 

2

 

300007

 

Cau on

 

Keep

 

O

/

 

Do

 

Not

 

Play

 

5

 

300008

 

Compactor

 

Safety

 

Rules

 ‐ 

English

 

2

 

300010

 

Danger

 

208

 

Volt

 

 

300013

 

Danger

 

Con

fi

ned

 

Space

 

Lock

 

Out

 

4

 

300014

 

Danger

 

Crushing/

 

Shearing

 

Hazard

  

6

 

300015

 

Danger

 

Hazards

 

Compactor

 

3

 

300017

 

Danger

 

Lock

 

Out

 

Power

 

Unit

 

1

 

300018

 

Danger

 

Shock/

 

Arc

 

Flash

 

1

 

300019

 

Danger

 

Starts

 

Automa cally

 

2

 

Loca on

 

Doors–

 

inside

 

and

 

outside

 

Feed

 

areas

 

and

 

controls

 

All

 

sides

 

of

 

compactor

 

Feed

 

areas

 

and

 

controls

 

 

Hopper–

 

all

 

sides

 

Hopper–

 

all

 

sides,

 

inside

 

doors,

 

access

 

panel

 

Access

 

panels

 

and

 

adjacent

 

surfaces.

 

Control

 

panel

 

face

 

(Power

 

Unit)

 

Control

 

panel

 

face

 

(Power

 

Unit)

 

Areas

 

of

 

access

 

and

 

feed

 

300012

 

Danger

 

460

 

Volt

  

 

 

300011

 

Danger

 

220

240

 

Volt

      

Control

 

panel

 

face

 

(Power

 

Unit)

 

1

 

300009

 

Compactor

 

Safety

 

Rules

 ‐ 

Español

  

Feed

 

areas

 

and

 

controls

 

2

 

List

 

of

 

Safety

 

Decals

 

Pick

 

up

 

hook

 

used

 

to

 

safely

 

move

 

compactor

 

using

 

crane

 

or

 

other

 

suitable

 

li ing

 

equipment.

 

 

Note:

 

Remove

 

a er

 

install.

 

Summary of Contents for VERSA-PAK P50

Page 1: ...Apartment Compactor PSI Waste Equipment Services Inc Safety Opera on and Installa on Manual 11 23 2020 v P50BA...

Page 2: ...te Space Requirements 4 Electrical Slab Requirements 5 Sec on 3 Opera on Changing Containers 6 Control Panel 7 Normal Opera onal Characteris cs Manual 8 Normal Opera onal Characteris cs Auto 9 Fault C...

Page 3: ...e compactor on the market About this manual This manual provides the installer owner and operator with informa on needed to install maintain and operate the P50 compactor You must also comply with loc...

Page 4: ...Lock Out Power Unit 1 300018 Danger Shock Arc Flash 1 300019 Danger Starts Automa cally 2 Loca on Doors inside and outside Feed areas and controls All sides of compactor Feed areas and controls Hopper...

Page 5: ...PSI Waste Equipment Services Inc P50 Apartment Compactor Sec on 1 Safety and Responsibili es 2 Safety Decals...

Page 6: ...o employees Ensure employees understand and follow Operator Responsibili es and safety decals Ensure only authorized and qualified employees have access to the compactor Properly maintain compactor an...

Page 7: ...PSI Waste Equipment Services Inc P50 Apartment Compactor Sec on 2 Installa on 4 Site Space Requirements...

Page 8: ...l Element Fuse Max Circuit Breaker Max Minimum Wire Size 60 deg C 3HP 208 1Ph 18 7 35 50 10 3HP 230 1Ph 17 30 45 10 5HP 208 3Ph 16 7 30 45 10 5HP 230 3Ph 15 2 30 40 12 5HP 460 3Ph 7 6 15 20 12 The P50...

Page 9: ...fore unhooking container make sure ram is in rear posi on Press the E Stop bu on and turn the key switch to the O posi on Unlatch container as shown Remove container and place in staging area Roll new...

Page 10: ...PSI Waste Equipment Services Inc P50 Apartment Compactor Sec on 3 Opera on 7 Control Panel...

Page 11: ...mmediately move forward to begin another cycle If the E STOP is pressed a door is opened or the KEY SWITCH is turned o the cycle will stop and the motor will shut o When the START bu on is pressed aga...

Page 12: ...to look for more trash Momentary blocking of the eye falling trash will have no e ect When the eye is blocked for 5 full sec onds the warning horn will sound If the eye con nues to stay blocked for th...

Page 13: ...me normal opera on See se ngs below for more informa on Danger Only qualified and authorized personnel should a empt the following To use Sleep Mode you ll have to set the clock on the Versa Pak syste...

Page 14: ...Ram Face Force psi 27 1 Pack Out Ram Face Force psi 31 5 Ram Penetra on in 5 Weight lbs 1 876 Electrical Tri Volt Motor 208 230 460 5HP Electric Control Voltage 120 VAC Hydraulic Hydraulic Pump Capac...

Page 15: ...PSI Waste Equipment Services Inc P50 Apartment Compactor Sec on 5 Maintenance 12 Parts...

Page 16: ...ure the padlock prevents the disconnect from being turned on Keep the key with you 5 Now make sure you can not start the compactor 6 Relieve pressure from hydraulic system by pushing in on each side o...

Page 17: ...1 2 of top of s ck If more than 1 gallon 5 8 of oil is being lost per year call a qualified compactor repair company and have them check the cylinders and hoses for leaks Clean trash from under and ar...

Page 18: ...PSI Waste Equipment Services Inc P50 Apartment Compactor Sec on 5 Maintenance 15 Hydraulic Schema c...

Page 19: ...PSI Waste Equipment Services Inc P50 Apartment Compactor Sec on 5 Maintenance 16 Electrical Schema c...

Page 20: ...isuse negligence or other losses not caused by defects in manufacturing Normal maintenance cleaning Abrasion or damage to exterior hoses Loss of use temporary service consequen al or incidental damage...

Reviews: