background image

Quick Start Guide

Kit Contents

   WireXpert (Local and Remote)   

Headset

   CAT6A Channel Adapters 

 

12V DC Power Adapters

   CAT6A Permanent Link Adapters 

Soft-case

   USB Flash Drive   

 

 

Calibration Certificate

The WX4500 WireXpert kit comes with all the accessories necessary 

to perform a certification test up to CAT6A or Class EA limit in either 

channel or permanent link configuration. If you have purchased 

the Fiber or Class FA certification options, you will be provided with 

additional equipments.

 

A calibration certificate with the date of calibration and validity 

guarantees accuracy of measurements on your WireXpert for that 

period. The local and remote units are identical physically, however 

the test results are stored only in the local unit.

Power ON/OFF Button

Speaker

DC Input

10/100 Mbit/s Ethernet Port

USB Host Port

USB Device Connector

Mic / Headphone Port

5

6

Using the eXport software

1. Launch eXport software.

2. Create a new project by going to File > New Project or click 

3. To import saved results, go to 

• Import > Device for direct USB connection or click 

• Import > USB Flash drive for importing from USB flash drives or click 

• Import > From PC for importing from local hard drives

4. To view detailed results, double click on the cable label and a new window 

with comprehensive results and plots will be opened.

List-Based Testing

Hierarchy Label List Generation

The Label List Generator generates cable labels in customizable hierarchical 

(building name-> floor-> telecom room-> rack-> panel-> port) order before 

conducting cable certifications, reducing effort from keying labels after 

every test. The pre-defined labels imported into the device will prevent 

duplicate testing when conducting in non-sequential orders.

To create label list, 

1. Launch eXport and go to Tools > Label List Generator.

2. Enter the first and last label of each tier into the respective fields. 

3. Tiers can be disabled by unchecking if it is not applicable.

4. Click the “Save” button to save the list based labels.

5. Insert USB flash drive to PC and click the “Export to USB” to begin export.

WireXpert4500_Copper_IT_EN_Q_201510_302

To load label list, 

1. Insert USB flash drive to Local unit of WireXpert.

2. Select “Label List” and select the label list you want to import.

3. Select “Copy Label Files”.

4. Press the “SETUP” button > Project Settings > Label Source

5. Select “List Based Testing” and select the label that has just been imported.

6. Press the AUTOTEST button to view list and select label for test.

After every test, 

PASS

 and  

FAIL

 will be indicated accordingly.

For more information, please contact us at 

wirexpert@psiberdata.com

 or visit 

www.psiberdata.com

Reviews: