background image

 

LD160 REV.E1-2 

4. 

DIP 6 & DIP 7 & DIP 8 

  CONTROLS OUTPUT A EXTEND TIME

 

DIP NO. 

DIP 6 

DIP 7 

DIP 8 

EXTEND 

DETECT 

 

DIP MODE 

OFF

■□

 

OFF

■□

 

OFF

■□

 

No extend 

Output A   

 

□■

ON 

OFF

■□

 

OFF

■□

 

2 seconds 

Output A   

 

OFF

■□

 

□■

ON 

OFF

■□

 

5 seconds 

Output A   

 

□■

ON 

□■

ON 

OFF

■□

 

8 seconds 

Output A   

 

OFF

■□

 

OFF

■□

 

□■

ON 

10 seconds 

Output A   

 

□■

ON 

OFF

■□

 

□■

ON 

15 seconds 

Output A   

 

OFF

■□

 

□■

ON 

□■

ON 

20 seconds 

Output A   

 

□■

ON 

□■

ON 

□■

ON 

30 seconds 

Output A   

 

5. 

DIP9 & DIP10 

  FREQUENCY SELECTION(40K to 80KHz)

 

DIP NO. 

DIP 9 

DIP 10 

FREQUENCCY RANG 

DIP MODE 

OFF

■□

 

OFF

■□

 

High frequency 

□■

ON    OFF

■□

 

Medium-High frequency. 

OFF

■□

 

□■

ON 

Medium frequency. 

□■

ON 

□■

ON 

Low frequency. 

* 

When more than two loops are used, please set up different frequencies in order to eliminate the crosstalk. 

(4) RESET Button 

RESET button can reset the detector.    RESET is needed whenever a frequency is changed. 

 

3.

 

Installation Information 

(1) Teflon loop is recommended and the maximum length could reach 

500 meter. 

(2) Loops should have 3 to 5 rotaries; the remains of the cable need 

to have a helix every 15 cm. 

(3) Typical saw cut loop installation

 

 

(4) The more rotaries of a loop, the lower of the frequency. 

(5) The appropriate way of the rotation of a loop is 1.0 to 2.0M in 

length and 0.8 to 1.2M in width. 

(6) The loop should be installed in an area where has no electric 

overhead door near by. 

(7) Any vehicle with a speed of no more than 120Km/Hr will be 

detected. 

(8) The specification for both outputs is 110VAC/10A. 

(9) Appropriate way to correct a failed detector: 

 

Press “RESET” button.     

  Check the DETECT and POWER LED

 

If POWER RED LED is dark, check AC power source and fuse (0.5A, inside of the detector). 

If DETECT GREEN LED is blinking, the loop may have a short circuit. 

If DETECT GREEN LED is blinking very slowly, loop does not have enough rotaries. 

If DETECT GREEN LED is blinking very rapidly, loop has too many rotaries. 

  When loop has not enough rotaries (frequency will also be too high), change DIP switch to low frequency. 

  When loop has too many rotaries (frequency will also be too low), increase the loop rotaries. 

PERIMETER (M) 

NO. OF TURNS 

3 ~ 4 M 

4 ~ 6 M 

6 ~ 10 M 

10 ~ 20 M 

20M ~ UP 

Reviews: