PT113
Instruction Manual
5
3 SPECIFICATIONS
General common specifications
A/D Converter
A/D converter type
24 bit Delta-Sigma ratiometric with integral analogue and digital filters
Conversion Rate
Up to 800 conversions per second.
Input sensitivity
0.1μV/dV/d
Analog input range
0 mV to +18 mV (unipolar weighing); -18mV to +18mV (bidirectional force)
Zero offset adjustment range
-18mV to +18mV
Resolution
Transmitted resolution
500-100 000 in weighing or force mode. 1 000 000 or 2 000 000 in count mode
Internal resolution
up to 8 000 000
Non-linearity, temp. coefficient Within 0.0015% FS, < 2 ppm/ºC
Scale Calibration and Functions
Calibration
Span calibration with weights, even without without zero calibration.
vCal for calibration by direct entry of load cell characteristics.
Calibration of span and zero by fieldbus commands.
Digital filter
10 step programmable adaptive digital filter.
Weighing functions
Tare, zeroing, auto zero track, motion detection, auto-zero at power up, tare
save at power off, Hi-resolution.
Load cells
Excitation
5 VDC, 86 mA max.
Number of load cells
Up to 6 load cells 350Ω, 12 load cells 700Ω, in parallel.
Load cell connection
4 or 6 wire technique.
Cable length: maximum 250 m/mm² for 6-wire connection
Communication
RS-232 and modes
9600 baud 8N1. Continuous output, Command or BSI, Modbus RTU modes.
Response Speed
< 4mS response delay from read/write commands.
Power Connection
All Models
11 to 28VDC 300mA.
Environment and Enclosure
Operating Environment
-10 °C to +40 °C; 85% RH max., non-condensing.
Enclosure
Polyamide, for DIN-rail mount, protection class IP20. View A for PT113MB,
view B for PT113EN, PT113PB, PT113PN and PT113CO
Illustration 1: PT113 Dimensions